Searches / Arquivos Brasileiros De Oftalmologia[JOURNAL]

Arquivos Brasileiros De Oftalmologia[JOURNAL]

Sun 200 papers
RSS

Clinical outcomes and significance of postoperative ultrasound biomicroscopy in patients with Boston type 1 keratoprosthesis.

Tas AY, Abay B, Muftuoglu O

Arq Bras Oftalmol · 2024 · PMID 39109743 · Full text

PURPOSE: To determine the clinical outcomes in patients after type 1 Boston keratoprosthesis surgery and the significance of ultrasound biomicroscopy imaging for postoperative follow-up. METHODS: This retrospective analy... PURPOSE: To determine the clinical outcomes in patients after type 1 Boston keratoprosthesis surgery and the significance of ultrasound biomicroscopy imaging for postoperative follow-up. METHODS: This retrospective analysis included 20 eyes of 19 patients who underwent corneal transplantation with type 1 Boston keratoprosthesis between April 2014 and December 2021. Data on patient demographics, preoperative diagnosis, visual acuity, and postoperative clinical findings were analyzed. RESULTS: Type 1 Boston keratoprosthesis implantation resulted in intermediate- and long-term positive outcomes. However, blindness and other serious complications such as glaucoma, retroprosthetic membrane formation, endophthalmitis, or retinal detachment also occurred. The use of ultrasound biomicroscopy imaging allowed for better evaluation of the back of the titanium plate, anterior segment structures, and the relationship of the prosthesis with surrounding tissues, which provided valuable postoperative information. CONCLUSION: Regular lifetime monitoring and treatment are necessary in patients who undergo Boston type 1 keratoprosthesis implantation for high-risk corneal transplantation. ultrasound biomicroscopy imaging can be a valuable imaging technique for the evaluation of patients with Boston type 1 keratoprosthesis, providing important information on anterior segment anatomy and potential complications. Further studies and consensus on postoperative follow-up protocols are required to optimize the management of patients with Boston type 1 keratoprosthesis.

Meibography health score: a simple grading system for isotretinoin-induced meibography alterations on patients with acne vulgaris.

Andrade FMX, Hirai F, Wakamatsu TH … +2 more , Medina RIS, Freitas D

Arq Bras Oftalmol · 2024 · PMID 39109742 · Full text

PURPOSE: To develop a simple, subjective, and reliable grading scale for isotretinoin-induced meibography changes. METHODS: After analyzing meibography images obtained from systemic isotretinoin users, a grading scale wa... PURPOSE: To develop a simple, subjective, and reliable grading scale for isotretinoin-induced meibography changes. METHODS: After analyzing meibography images obtained from systemic isotretinoin users, a grading scale was proposed and named "meibography health score." The score ranged from 1 to 3, with decreasing gland reflectivity and identifiable margins. A total of 11 medical professionals were asked to grade 10 meibography images obtained from isotretinoin users using the proposed scale and were divided into three groups: (A) ophthalmologists with experience with meibography, (B) ophthalmologists with no experience with meibography, and (C) radiologists. The kappa statistic was determined to test interrater reliability. RESULTS: The overall kappa was approximately 0.64. The kappa scores for Groups A, B, and C were 0.78, 0.59, and 0.90, respectively. Grade 2 had the lowest kappa scores (0.62, 0.35, and 0.82 for A, B, and C, respectively) and grade 3 the highest (0.78, 0.90, and 1.0 for A, B and C, respectively). Furthermore, Group C had the highest kappa scores and Group B the lowest. CONCLUSION: The meibography health score exhibited good interrater reliability, particularly in severe cases.

Choroiditis following severe acute respiratory syndrome coronavirus 2 infection in unvaccinated identical twins.

Mello LGM, Lubiana LG, Hirata CE … +2 more , Monteiro MLR, Yamamoto JH

Arq Bras Oftalmol · 2024 · PMID 39109741 · Full text

Unvaccinated identical twins developed bilateral anterior uveitis soon after the onset of coronavirus disease 2019 symptoms. During follow-up, both patients developed choroiditis, and one twine developed posterior scleri... Unvaccinated identical twins developed bilateral anterior uveitis soon after the onset of coronavirus disease 2019 symptoms. During follow-up, both patients developed choroiditis, and one twine developed posterior scleritis and serous retinal detachment. Prompt treatment with oral prednisone ameliorated the lesions, and no recurrence was observed at the 18-month follow-up. Choroiditis may rarely be associated with severe acute respiratory syndrome coronavirus 2 infection, and it responds well to corticosteroid therapy. Although the exact mechanism is unknown, we hypothesize that the virus may act as an immunological trigger for choroiditis.

Comparison of safety and effectiveness of micropulse transscleral cyclophotocoagulation and "slow cook" diode laser transscleral cyclophotocoagulation in patients with refractory open-angle glaucoma.

Russ HHA, Seixas RCS, Maestrini HA … +5 more , Balbino M, Fernandes TAP, Lima NVDA, Lopes NLV, Rodrigues Neto TDS

Arq Bras Oftalmol · 2024 · PMID 39109740 · Full text

PURPOSE: This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and "slow cook" transscleral cyclophotocoagulation in patients wit... PURPOSE: This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and "slow cook" transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma. METHODS: We included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B). RESULTS: We included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was -0.10 ± 0.35 and -0.074 ± 0.16 in the micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the "slow cook" and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the "slow cook" transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p<0.001). CONCLUSION: Both techniques reduced intraocular pressure effectively.

Intraocular pressure modulation with thermal stimuli.

Oliveira TCB, Ferreira JLM, Lima HT … +2 more , Bezerra Filho COA, Ribeiro JC

Arq Bras Oftalmol · 2024 · PMID 39109739 · Full text

PURPOSE: This study aimed to determine whether early-stage intraocular pressure can be modulated using a thermal face mask. METHODS: In this prospective clinical study, healthy participants were randomized on a 1:1:1 all... PURPOSE: This study aimed to determine whether early-stage intraocular pressure can be modulated using a thermal face mask. METHODS: In this prospective clinical study, healthy participants were randomized on a 1:1:1 allocation ratio to three mask groups: hypothermic (G1), normothermic (G2), and hyperthermic (G3). After randomization, 108 eyes from 108 participants were submitted to clinical evaluations, including measurement of initial intraocular pressure (T1). The thermal mask was then applied for 10 minutes, followed by a second evaluation of intraocular pressure (T2) and assessment of any side effects. RESULTS: The hypothermic group (G1) showed a significant reduction in mean intraocular pressure between T1 (16.97 ± 2.59 mmHg) and T2 (14.97 ± 2.44 mmHg) (p<0.001). G2 showed no significant pressure difference between T1 (16.50 ± 2.55 mmHg) and T2 (17.00 ± 2.29 mmHg) (p=0.054). G3 showed a significant increase in pressure from T1 (16.53 ± 2.69 mmHg) to T2 (18.58 ± 2.95 mmHg) (p<0.001). At T1, there was no difference between the three study groups (p=0.823), but at T2, the mean values of G3 were significantly higher than those of G1 and G2 (p<0.00). CONCLUSION: Temperature was shown to significantly modify intraocular pressure. Thermal masks allow the application of temperature in a controlled, reproducible manner. Further studies are needed to assess the duration of these effects and whether they are reproducible in patients with pathologies that affect intraocular pressure.

Clinical, epidemiological, and care profile of hospitalized patients with retinoblastoma in Brazil.

Barbosa AC, Magalhães-Barbosa MC, Colombini GNUI … +1 more , Prata-Barbosa A

Arq Bras Oftalmol · 2024 · PMID 39109738 · Full text

PURPOSE: To describe the epidemiological and clinical profile of hospitalized patients with retinoblastoma in Brazil. METHODS: Using data from the Hospital Cancer Registry of the Instituto Nacional de Câncer, patients wi... PURPOSE: To describe the epidemiological and clinical profile of hospitalized patients with retinoblastoma in Brazil. METHODS: Using data from the Hospital Cancer Registry of the Instituto Nacional de Câncer, patients with the morphological codes of retinoblastoma who were diagnosed between 2000 to 2018, aged 0-19 years, and followed up in registered hospitals (analytical cases) were selected. The relative and absolute frequencies of demographic, clinical, diagnostic, therapeutic, and outcome variables were described. Hospital performance indicators were calculated and compared between hospitals qualified and not qualified to treat pediatric oncology cases and between hospitals with different case volumes (<20, 20-75, >75 cases). RESULTS: Of the 2,269 identified analytical cases from 86 institutions, 48% were from the Southeast, 54% were male, and 66% were aged <4 years. The proportion of missing data (NA) was too high for several variables. Approximately 84% of the patients were from the public health system, 40% had a positive family history, and 88% had unilateral involvement. The first treatment included surgery in 58.3% of the patients (NA=2), Approximately 36.6% of these patients achieved complete remission, 10.8% achieved partial remission, and 12.7% died (NA=59%). Hospital performance indicators were within the target in >90% of the patients. The median time between the first appointment and diagnosis (6 days, interquartile range [IQR] 1-14) was significantly lower and the median time to death was longer (343 days, IQR, 212-539) in high-volume hospitals (>75 cases) than in medium- and low-volume hospitals. CONCLUSIONS: Despite the high proportion of missing data, we found that the delay in diagnosis is due to prehospital factors. Additionally, there is a need for educational programs for healthcare professionals and families that emphasize early identification and referral to specialized centers. Future studies should focus on the impact of Hospital Cancer Registry data completeness on outcomes, causes of delay in diagnosis, regional inequalities, and barriers to accessing specialized services.

Evaluation of perioperative pachymetry of thin corneas during corneal crosslinking using hypo-osmolar riboflavin and hydroxypropyl methylcellulose.

Matsumoto FK, Tojar M, Souza LB

Arq Bras Oftalmol · 2024 · PMID 39109737 · Full text

PURPOSE: This study aimed to analyze variations in intraoperative corneal thickness during corneal cross-linking in patients with keratoconus and to investigate its possible correlation with presurgical maximal keratomet... PURPOSE: This study aimed to analyze variations in intraoperative corneal thickness during corneal cross-linking in patients with keratoconus and to investigate its possible correlation with presurgical maximal keratometry (Kmax) and pachymetry. METHODS: This was a prospective case series. We used a method similar to the Dresden protocol, with the application of hydroxypropyl methylcellulose 0.1% hypo-osmolar riboflavin in corneas between 330 and 400 µm after epithelium removal. Corneal thickness was measured using portable calipers before and immediately after epithelium removal, and 30 and 60 min after the procedure. RESULTS: The 30 patients in this study were followed up for one year. A statistically significant difference was observed in pachymetry values during the intraoperative period (p<0.0001) and an increase of 3.05 µm (95%C1: 0.56-5.54) for each diopter was seen after epithelium removal (p0.019). We found an average Kmax difference of -2.12 D between men and women (p0.013). One year after treatment, there was a statistically significant reduction in pachymetry (p<0.0001) and Kmax (p0.0170) values. CONCLUSIONS: A significant increase in pachymetry measurements was seen during the procedure, and most patients showed a regression in Kmax and pachymetry values one year after surgery.

Protein profile of purified plasma- and aqueous humor-derived extracellular vesicles from patients with ocular toxoplasmosis.

Costa DF, Pessuti CL, Tsering T … +7 more , Abdouh M, Ribeiro K, Nascimento H, Commodaro AG, Burnier JV, Belfort R, Burnier MN

Arq Bras Oftalmol · 2024 · PMID 39109736 · Full text

PURPOSE: To characterize the extracellular vesicle protein cargo in the aqueous humor and plasma of patients with ocular toxoplasmosis. METHODS: Aqueous humor and plasma were collected from six patients with active ocula... PURPOSE: To characterize the extracellular vesicle protein cargo in the aqueous humor and plasma of patients with ocular toxoplasmosis. METHODS: Aqueous humor and plasma were collected from six patients with active ocular toxoplasmosis and six patients with cataract. Extracellular vesicles were isolated, and western blotting and mass spectrometry were performed for protein analysis. RESULTS: All plasma samples from patients with ocular toxoplasmosis and cataract were positive for the tetraspanins CD63 and TSG101. However, the aqueous humor from patients with ocular toxoplasmosis was positive only for CD63. Sixty-seven new unreported proteins were identified in the aqueous humor and plasma of patients with the ocular toxoplasmosis and cataract. Of the 67 proteins, 10 and 7 were found only in the cataract and ocular toxoplasmosis groups, respectively. In general, these proteins were involved in immune system activation and retina homeostasis and were related to infections and retina-associated diseases. CONCLUSION: The distinct protein signatures between ocular toxoplasmosis and cataract may be helpful in the differential diagnosis of ocular toxoplasmosis. However, more studies are needed to better understand the role of these proteins in the pathogenesis of ocular toxoplasmosis.

Anterior lamellar corneoscleral keratoplasty for the management of corneal thinning following treatment with mitomycin-C and interferon to treat highly suspected ocular surface squamous neoplasia: a case report.

Moreira PPDVR, Longo D, Polisuk M … +2 more , Carmona TA, Ambrosio R

Arq Bras Oftalmol · 2024 · PMID 39109735 · Full text

A patient presented with corneoscleral thinning five months after the treatment of suspected ocular squamous surface neoplasia with mitomycin-C and interferon. For tectonic and aesthetic purposes, we decided to perform l... A patient presented with corneoscleral thinning five months after the treatment of suspected ocular squamous surface neoplasia with mitomycin-C and interferon. For tectonic and aesthetic purposes, we decided to perform lamellar corneoscleral transplantation. The approach used established new tectonic support and corneal homeostasis. This technique might be an option in similar cases.

Night-time blood pressure dipping, but not 24-h blood pressure level, is linked to increased 24-h ocular volume slope.

Skrzypecki J, Szymański FM, Przybek-Skrzypecka J … +4 more , Izdebska J, Ryś-Czaporowska A, Filipiak KJ, Szaflik JP

Arq Bras Oftalmol · 2024 · PMID 39109734 · Full text

PURPOSE: This study investigated the relationship between blood pressure and intraocular pressure in treatmentnaive, non-glaucoma patients with different blood pressure statuses, focusing on the 24-h ocular volume and no... PURPOSE: This study investigated the relationship between blood pressure and intraocular pressure in treatmentnaive, non-glaucoma patients with different blood pressure statuses, focusing on the 24-h ocular volume and nocturnal blood pressure decline. METHODS: Treatment-naive, non-glaucoma patients undergoing hypertension evaluation were enrolled as study participants. Simultaneous 24-h ambulatory blood pressure measurement and 24-h ocular volume recording with a contact lens sensor. We also compared ocular volume curve parameters between normotensive and hypertensive patients, as well as between those with and without nocturnal blood pressure decline. RESULTS: A total of 21 patients, including 7 normotensive and 14 treatment-naive hypertensive individuals, were included in the study. of them, 11 were dippers and 10 were non-dippers. No significant difference in the 24-h ocular volume slope was observed between the hypertensive and normotensive patients (p=0.284). However, dippers had a significantly higher 24-h ocular volume slope (p=0.004) and nocturnal contact lens sensor output (p=0.041) than non-dippers. CONCLUSION: Nocturnal blood pressure decline, rather than the blood pressure level, is associated with the increased 24-h ocular volume slope and nocturnal ocular volume. Further studies are required to determine whether the acceleration of glaucoma progression in dippers is primarily due to low blood pressure, high intraocular pressure, or a combination of both.

Unilateral hemi-central retinal artery occlusion as a presenting sign of Susac syndrome.

Hokazono K, Fagundes MDC, Silva AFFD … +3 more , Minku CF, Teixeira BCA, Monteiro MLR

Arq Bras Oftalmol · 2024 · PMID 39109733 · Full text

A young woman presented at our clinic with sudden visual loss in the right eye, recurrent vertigo, and right-sided tinnitus. We performed a complete ophthalmological evaluation. This revealed effects of the condition on... A young woman presented at our clinic with sudden visual loss in the right eye, recurrent vertigo, and right-sided tinnitus. We performed a complete ophthalmological evaluation. This revealed effects of the condition on the small arterioles of the peripheral retina. Susac syndrome is characterized by the clinical triad of retinal arteriolar occlusions, cochleovestibular manifestations, and encephalopathy (which can be identified by neuroimaging abnormalities). Early diagnosis and immunosuppressive therapy improved the patient's visual acuity and the remission of her other symptoms. Hemi-central retinal artery occlusion is an atypical neuro-ophthalmological finding in this disease. However, its identification as a sign of Susac syndrome may facilitate timely diagnosis and accurate treatment.

Quality of life in patients with Graves' orbitopathy submitted to orbital decompression: comparison between balanced and inferomedial techniques.

Leite CA, Pereira TS, Chiang J … +3 more , Moritz RB, Gonçalves ACP, Monteiro MLR

Arq Bras Oftalmol · 2024 · PMID 39109703 · Full text

PURPOSE: To compare inferomedial wall orbital decompression to balanced medial plus lateral wall orbital decompression in patients with Graves' orbitopathy in the inactive phase with regard to exophthalmos reduction and... PURPOSE: To compare inferomedial wall orbital decompression to balanced medial plus lateral wall orbital decompression in patients with Graves' orbitopathy in the inactive phase with regard to exophthalmos reduction and the effects on quality of life. METHODS: Forty-two patients with inactive Graves' orbitopathy were randomly divided into two groups and submitted to one of two orbital decompression techniques: inferomedial wall orbital decompression or medial plus lateral wall orbital decompression. Preoperative and postoperative assessments included Hertel's exophthalmometry and a validated Graves' orbitopathy quality of life questionnaire. The results of the two groups were compared. RESULTS: Compared to preoperative measurement, exophthalmos reduction was statistically significant in both groups (p<0.001) but more so in patients undergoing medial plus lateral wall orbital decompression (p=0.010). Neither orbital decompression techniques increased the visual functioning subscale score on the Graves' orbitopathy quality of life questionnaire (inferomedial wall orbital decompression p=0.362 and medial plus lateral wall orbital decompression p=0.727), but a statistically significant difference was observed in the score of the appearance subscale in patients submitted to medial plus lateral wall orbital decompression (p=0.006). CONCLUSIONS: Inferomedial wall orbital decompression is a good alternative for patients who do not require large exophthalmos reduction. However, medial plus lateral wall orbital decompression offers greater exophthalmos reduction and greater improvement in appearance (higher Graves' orbitopathy quality of life questionnaire scores), making it a suitable option for esthetic-functional rehabilitation.

Guidelines for preventing and slowing myopia progression in Brazilian children.

Ejzenbaum F, Schaefer TMC, Cunha C … +5 more , Rossetto JD, Godinho IF, Nakanami CR, Noma RK, Hopker LM

Arq Bras Oftalmol · 2024 · PMID 39109702 · Full text

This document on myopia control is derived from a compilation of medical literature and the collective clinical expertise of an expert committee comprising members from the Brazilian Society of Pediatric Ophthalmology an... This document on myopia control is derived from a compilation of medical literature and the collective clinical expertise of an expert committee comprising members from the Brazilian Society of Pediatric Ophthalmology and the Brazilian Society of Contact Lenses and Cornea. To manage myopia in children, the committee recommends corneal topography and biannual visits with cycloplegic refraction, along with annual optical biometry. For fast-progressing myopia, biannual biometry should be considered. Myopic progression is defined as an annual increase in spherical equivalent greater than 0.50 D/year or in axial length greater than 0.3 mm (until 10 years old) or 0.2 mm (above 11 years). The proposed treatments for myopia progression include environmental control, low concentration atropine, defocus glasses, contact lenses, or Ortho-K lenses, and combinations of these methods may be necessary for uncontrolled cases. Treatment should be sustained for at least 2 years. This document serves as a comprehensive guideline for diagnosing, treating, and monitoring pre-myopic and myopic children in Brazil.

Who should finance science? A consideration about publication costs.

Kara-Junior N

Arq Bras Oftalmol · 2024 · PMID 39016425 · Full text

Abstract loading — click title to view on PubMed.

Morgagnian cataract.

Marinho F, Almeida NBM, Kara-Junior N

Arq Bras Oftalmol · 2024 · PMID 39016424 · Full text

Abstract loading — click title to view on PubMed.

Macular perfusion changes in people administered two types of COVID-19 vaccines: comment.

Daungsupawong H, Wiwanitkit V

Arq Bras Oftalmol · 2024 · PMID 39016423 · Full text

Abstract loading — click title to view on PubMed.

Segmental vitiligo of the lid margin with leukotrichia of lashes in a child.

Rajagopal J

Arq Bras Oftalmol · 2024 · PMID 39016422 · Full text

Abstract loading — click title to view on PubMed.

An unexpected case of a large metallic intraorbital foreign body.

Yao B, Liu G, Wang B

Arq Bras Oftalmol · 2024 · PMID 39016421 · Full text

Abstract loading — click title to view on PubMed.

The open access and dissemination of predatory journals.

Kara-Junior N

Arq Bras Oftalmol · 2024 · PMID 38808912 · Full text

Abstract loading — click title to view on PubMed.

Endoscopy changing the treatment of congenital nasolacrimal duct obstruction.

Schellini SA, Akaishi PMS

Arq Bras Oftalmol · 2024 · PMID 38808911 · Full text

Abstract loading — click title to view on PubMed.

← Prev Page 9 of 10 Next →

About

Frequency
Sun
Papers found
200
RSS feed
Subscribe