Searches / Critical Ultrasound Journal[JOURNAL]

Critical Ultrasound Journal[JOURNAL]

Sun 167 papers
RSS

The relationship between single and two-dimensional indices of left ventricular size using hemodynamic transesophageal echocardiography in trauma and burn patients.

Younan D, Beasley TM, Pigott DC … +5 more , Gibson CB, Gullett JP, Richey J, Pittet JF, Zaky A

Crit Ultrasound J · 2017 Oct · PMID 29022204 · Full text

BACKGROUND: Conventional echocardiographic technique for assessment of volume status and cardiac contractility utilizes left ventricular end-diastolic area (LVEDA) and fractional area of change (FAC), respectively. Our g... BACKGROUND: Conventional echocardiographic technique for assessment of volume status and cardiac contractility utilizes left ventricular end-diastolic area (LVEDA) and fractional area of change (FAC), respectively. Our goal was to find a technically reliable yet faster technique to evaluate volume status and contractility by measuring left ventricular end-diastolic diameter (LVEDD) and fractional shortening (FS) in a cohort of mechanically ventilated trauma and burn patients using hemodynamic transesophageal echocardiographic (hTEE) monitoring. METHODS: Retrospective chart review performed at trauma/burn intensive care unit (TBICU). Data on 88 mechanically ventilated surgical intensive care patients cared for between July 2013 and July 2015 were reviewed. Initial measurements of LVEDA, left ventricular end-systolic area (LVESA) and FAC were collected. Post-processing left ventricular end-systolic (LVESD) and end-diastolic diameters (LVEDD) were measured and fractional shortening (FS) was calculated. Two orthogonal measurements of LV diameter were obtained in transverse (Tr) and posteroanterior (PA) orientation. RESULTS: There was a significant correlation between transverse and posteroanterior left ventricular diameter measurements in both systole and diastole. In systole, r = 0.92, p < 0.01 for LVESD-Tr (mean 23.47 mm, SD ± 6.77) and LVESD-PA (mean 24.84 mm, SD = 8.23). In diastole, r = 0.80, p < 0.01 for LVEDD-Tr (mean 37.60 mm, SD ± 6.45), and LVEDD-PA diameters (mean 42.24 mm, SD ± 7.97). Left ventricular area (LVEDA) also significantly correlated with left ventricular diameter LVEDD-Tr (r = 0.84, p < 0.01) and LVEDD-PA (r = 0.90, p < 0.01). Both transverse and PA measurements of fractional shortening were significantly (p < 0.0001) and similarly correlated with systolic function as measured by FAC. Bland-Altman analyses also indicated that the assessment of fractional shortening using left ventricular posteroanterior diameter measurement shows agreement with FAC. CONCLUSIONS: Left ventricular diameter measurements are a reliable and technically feasible alternative to left ventricular area measurements in the assessment of cardiac filling and systolic function.

POCUS in perioperative medicine: a North American perspective.

De Marchi L, Meineri M

Crit Ultrasound J · 2017 Oct · PMID 28993991 · Full text

Ultrasound (US) performed at the point of care has found fertile ground in perioperative medicine. In the hands of anesthesiologists, transesophageal echocardiography (TEE) has become established as a powerful diagnostic... Ultrasound (US) performed at the point of care has found fertile ground in perioperative medicine. In the hands of anesthesiologists, transesophageal echocardiography (TEE) has become established as a powerful diagnostic and monitoring tool in the perioperative care of cardiac and non-cardiac patients. A number of point-of-care US (POCUS) applications are relevant to perioperative care, including airway, cardiac, lung and gastric US. Although guidelines exist to define the scope of practice for basic and advanced TEE, there remains a lack of such guidelines for perioperative point-of-care ultrasound (POCUS), despite a number of recent calls for action in the academic anesthesia community. POCUS training has been integrated into anesthesia residency curricula in Canada and the United States of America (USA). However, a nation-wide curriculum is still lacking. Many limitations to the development of perioperative POCUS curricula exist, including the need to define the scope of practice and design integrated longitudinal learning approaches. The main anesthesiologist societies in both the USA and Canada are promoting the development of guidelines and have introduced POCUS courses into their national conferences. Although bedside US imaging has been integrated into the curricula of many medical schools in North America, the need for specific national guidelines for the training and practice of POCUS in the perioperative setting by anesthesiologists is crucial to the further development of POCUS in perioperative medicine.

Time to correct the flow of corrected flow time.

Barjaktarevic I, Chiem A, Cannesson M

Crit Ultrasound J · 2017 Oct · PMID 28980175 · Full text

Recently published study of Ma et al. evaluates two relatively novel measures of fluid responsiveness, carotid blood flow and corrected carotid flow time (ccFT). Both measures have been recently quoted as possibly useful... Recently published study of Ma et al. evaluates two relatively novel measures of fluid responsiveness, carotid blood flow and corrected carotid flow time (ccFT). Both measures have been recently quoted as possibly useful, technically simple, and noninvasive dynamic tools in predicting fluid responsiveness. Recently, more research interest has been focused on ccFT and, intrigued by the data presented in this study, we discuss here the impact of the data presented in the paper of Ma et al. to the significance of this metric as a potential tool in the assessment of fluid responsiveness.

Bedside transcranial sonography monitoring in a patient with hydrocephalus post subarachnoid hemorrhage.

Najjar A, Denault AY, Bojanowski MW

Crit Ultrasound J · 2017 Sep · PMID 28956308 · Full text

BACKGROUND: Development of hydrocephalus can occur after subarachnoid hemorrhage (SAH). Typically, it is diagnosed with computed tomography, CT, scan. However, transcranial sonography (TCS) can be used particularly in pa... BACKGROUND: Development of hydrocephalus can occur after subarachnoid hemorrhage (SAH). Typically, it is diagnosed with computed tomography, CT, scan. However, transcranial sonography (TCS) can be used particularly in patients with craniotomy which removes the acoustic interference of the skull and allows a closer up visualization of brain structures through the skin. CASE PRESENTATION: We report a 73-year-old woman who was hospitalized for SAH and developed acute hydrocephalus requiring an external ventricular drain (EVD). In this patient, detection and monitoring of hydrocephalus was done and monitored with a small pocket-sized TCS device. Nine days after surgery, weaning of the EVD was attempted. Prior to EVD closure and removal, TCS showed a measurement of the 3rd ventricle at around 1.16 cm. On the third day, the patient deteriorated clinically and the TCS showed a dilated 3rd ventricle measuring 1.37 cm which correlated well with computed tomography and with clinical signs of active hydrocephalus as both her sensorium and communication were affected. Subsequently following EVD re-installation, on the next day, TCS showed that the 3rd ventricle dimension was reduced to 0.99 cm and the following day it went down to 0.69 cm. CONCLUSIONS: Patients with SAH and in particular those with a craniotomy can be monitored easily at the bedside with hand-held TCS for the development and monitoring of hydrocephalus.

Ultrasonography in trauma: a nation-wide cross-sectional investigation.

Weile J, Nielsen K, Primdahl SC … +4 more , Frederiksen CA, Laursen CB, Sloth E, Kirkegaard H

Crit Ultrasound J · 2017 Dec · PMID 28639253 · Full text

BACKGROUND: The Focused Assessment with Sonography in Trauma (FAST) protocol is considered beneficial in emergent evaluation of trauma patients with blunt or penetrating injury and has become integrated into the Advanced... BACKGROUND: The Focused Assessment with Sonography in Trauma (FAST) protocol is considered beneficial in emergent evaluation of trauma patients with blunt or penetrating injury and has become integrated into the Advanced Trauma Life Support (ATLS) protocol. No guidelines exist as to the use of ultrasonography in trauma in Denmark. We aimed to determine the current use of ultrasonography for assessing trauma patients in Denmark. METHODS: We conducted a nation-wide cross-sectional investigation of ultrasonography usage in trauma care. The first phase consisted of an Internet-based investigation of existing guidelines, and the second phase was a series of structured interviews of orthopedic surgeons, anesthesiologists, and radiologists on call in all hospitals receiving traumatized patients in Denmark. RESULTS: Guidelines were obtained from all 22 hospitals receiving traumatized patients in Denmark. Twenty-one (95.5%) of the guidelines included and recommended FAST as part of trauma assessment. The recommended person to perform the examination was the radiologist in n = 11 (50.0%), the surgeon in n = 6 (27.3%), the anesthesiologist in n = 1 (4.5%), and unspecified in n = 3 (13.6%) facilities. FAST indications varied between circulatory instability n = 8 (36.4%), team leader's discretion n = 6 (27.3%), abdominal trauma n = 3 (13.6%), and not specified n = 6 (27.3%). Telephone interviews revealed that exams were always n = 8 (36.4%) or often n = 4 (18.2%) registered in the patients' charts. The remaining n = 10 (45.5%) facilities either never registered n = 2 (9.1%), it was not possible to register n = 1 (4.5%), or unknown by the trauma leaders n = 7 (31.8%). Images were often stored in n = 1 (4.5%), never stored in n = 10 (45.5%), not possible to store in n = 2 (9.1%), and unknown in n = 9 (40.9%) facilities. CONCLUSION: Ultrasonography was used in a non-uniform fashion by multiple specialties in Danish trauma facilities. Very few images from FAST examinations were stored and documentation was scanty. National guidelines on application and documentation of ultrasonography in trauma are called for.

Transesophageal echocardiography in orthotopic liver transplantation: a comprehensive intraoperative monitoring tool.

Vetrugno L, Barbariol F, Baccarani U … +3 more , Forfori F, Volpicelli G, Della Rocca G

Crit Ultrasound J · 2017 Dec · PMID 28631103 · Full text

Intraoperative transesophageal echocardiography is a minimally invasive monitoring tool that can provide real-time visual information on ventricular function and hemodynamic volume status in patients undergoing liver tra... Intraoperative transesophageal echocardiography is a minimally invasive monitoring tool that can provide real-time visual information on ventricular function and hemodynamic volume status in patients undergoing liver transplantation. The American Association for the Study of Liver Diseases states that transesophageal echocardiography should be used in all liver transplant candidates in order to assess chamber sizes, hypertrophy, systolic and diastolic function, valvular function, and left ventricle outflow tract obstruction. However, intraoperative transesophageal echocardiography can be used to "visualize" other organs too; thanks to its proximity and access to multiple acoustic windows: liver, lung, spleen, and kidney. Although only limited scientific evidence exists promoting this comprehensive use, we describe the feasibility of TEE in the setting of liver transplantation: it is a highly valuable tool, not only as a cardiovascular monitoring, but also as a tool to evaluate lungs and pleural spaces, to assess hepatic vein blood flow and inferior vena cava anastomosis and patency, i.e., in cases of modified surgical techniques. The aim of this case series is to add our own experience of TEE as a comprehensive intraoperative monitoring tool in the field of orthotopic liver transplantation (and major liver resection) to the literature.

Right heart thrombus in transit: a series of two cases.

Otoupalova E, Dalal B, Renard B

Crit Ultrasound J · 2017 Dec · PMID 28620869 · Full text

Right heart thrombus in transit is an increasingly recognized medical emergency with very high mortality rate. Echocardiography helps to establish the diagnosis and can differentiate between right heart thrombi that resu... Right heart thrombus in transit is an increasingly recognized medical emergency with very high mortality rate. Echocardiography helps to establish the diagnosis and can differentiate between right heart thrombi that result from atrial fibrillation and those originating from deep venous thrombosis. We present two cases of right heart thrombus in transit diagnosed with echocardiography that were managed with different approaches.

A simplified lung ultrasound approach to detect increased extravascular lung water in critically ill patients.

Anile A, Russo J, Castiglione G … +1 more , Volpicelli G

Crit Ultrasound J · 2017 Dec · PMID 28612302 · Full text

BACKGROUND: The quantification of B-lines at lung ultrasonography is a valid tool to estimate the extravascular lung water (EVLW) in patients after major cardiac surgery. However, there is still uncertainty about the cor... BACKGROUND: The quantification of B-lines at lung ultrasonography is a valid tool to estimate the extravascular lung water (EVLW) in patients after major cardiac surgery. However, there is still uncertainty about the correlation between B-lines and EVLW in a general population of critically ill. AIM: To evaluate a simplified lung ultrasonographic assessment as a tool to estimate the EVLW in critically ill patients admitted to a polyvalent intensive care unit (ICU). METHODS: Nineteen consecutive critically ill patients requiring mechanical ventilation and hemodynamic monitoring were enrolled. Lung ultrasonography and the thermodilution methodology (PiCCO system) were performed by two independent operators. The positive scan at lung ultrasound was defined by visualization of at least 3 B-lines. We then compared the number of chest areas positive for B-lines with the EVLW index obtained by the invasive procedure. RESULTS: A significant correlation was found between the number of lung quadrants positive for B-lines and EVLW indexed using both actual body weight (rho = 0.612 p = 0.0053) and predicted body weight (rho = 0.493 p = 0.032). Presence of more than 3 positive lung quadrants showed a good performance in identifying an EVLW index value >10 ml/kg of actual body weight(area under the ROC 0.894; 95% CI 0.668-0.987 p < 0.0001). Presence of of more than 4 positive lung quadrants indentified an EVLW index value >10 ml/kg of predicted body weight (area under the ROC 0.8; 95% CI 0.556-0.945 p = 0.0048). CONCLUSION: A simplified lung ultrasound approach can by used as a reliable noninvasive bedside tool to predict EVLW in emergency and critically ill patients.

Applicability of a modified EFAST protocol (r-EFAST) to evaluate hemodynamically unstable patients after percutaneous cardiac intervention.

Vázquez Martínez JL, Quiñones Coneo KL, Villegas TV … +4 more , Sánchez Porras M, Macarrón CP, Pérez AC, Pineda LF

Crit Ultrasound J · 2017 Dec · PMID 28608268 · Full text

Percutaneous cardiac intervention is an invasive diagnostic and therapeutic technique which carries a significant complication rate. Although the usefulness of EFAST protocol is widely recognised, this paper will attempt... Percutaneous cardiac intervention is an invasive diagnostic and therapeutic technique which carries a significant complication rate. Although the usefulness of EFAST protocol is widely recognised, this paper will attempt to explore a modified approach involving a focused examination on the retroperitoneal (r-EFAST). We have provided examples of 3 cases where r-EFAST was used to detect retroperitoneal bleeding in critical situations.

Minimal training sufficient to diagnose pediatric wrist fractures with ultrasound.

Hedelin H, Tingström C, Hebelka H … +1 more , Karlsson J

Crit Ultrasound J · 2017 Dec · PMID 28484942 · Full text

BACKGROUND: In children, non-fractured wrists generally need no treatment and those that are fractured may only require a 3-week cast without any clinical follow-up. The ability to perform a point-of-care triage decision... BACKGROUND: In children, non-fractured wrists generally need no treatment and those that are fractured may only require a 3-week cast without any clinical follow-up. The ability to perform a point-of-care triage decision if radiographs are needed could improve patient flow and decrease unnecessary radiographs. The aim of this study was to evaluate the role of ultrasound (US) as a point-of-care triage tool for pediatric wrist injuries with limited training. METHODS: Physicians with no previous US experience attended a 1.5 h course in the use of US to diagnose distal radius fractures at the Emergency Department (ED). The physicians firstly used US to diagnose a potential fracture and, if the patient had a fracture, grouped the patient according to how they wanted him/her to be treated based on US. The physician then interpreted the subsequent radiographs and decided on a treatment based on this information. Consultant traumatologists and a senior radiologist established a gold standard for correct treatment and radiological diagnosis, respectively. RESULTS: One hundred and sixteen injuries in 115 patients were included. The ED physician identified 75 fractures on radiographs. With the exception of a minimal buckle fracture, all were identified on US. US had a tendency to interpret complete fractures on radiographs as incomplete (n = 7) leading to incorrect treatment decisions. CONCLUSIONS: In the hands of an US novice, US examination is comparable with radiographs as a point-of-care tool to distinguish a fractured wrist from a non-fractured one. US is not, however, as good as radiographs for placing fractured wrists into the correct treatment group. LEVEL OF EVIDENCE: Level III. Diagnostic study of non-consecutive patients.

Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements.

Ma IWY, Caplin JD, Azad A … +5 more , Wilson C, Fifer MA, Bagchi A, Liteplo AS, Noble VE

Crit Ultrasound J · 2017 Dec · PMID 28429291 · Full text

BACKGROUND: Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid b... BACKGROUND: Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardiac output. Consenting adult patients (n = 51) at Massachusetts General Hospital cardiac catheterization laboratory undergoing right heart catheterization between February and April 2016 were included. Carotid ultrasound images were obtained concurrently with cardiac output measurements, obtained by the thermodilution method in the absence of severe tricuspid regurgitation and by the Fick oxygen method otherwise. Corrected carotid flow time was calculated as systole time/√cycle time. Carotid blood flow was calculated as π × (carotid diameter)/4 × velocity time integral × heart rate. Measurements were obtained using a single carotid waveform and an average of three carotid waveforms for both measures. RESULTS: Single waveform measurements of corrected flow time did not correlate with cardiac output (ρ = 0.25, 95% CI -0.03 to 0.49, p = 0.08), but an average of three waveforms correlated significantly, although weakly (ρ = 0.29, 95% CI 0.02-0.53, p = 0.046). Carotid blood flow measurements correlated moderately with cardiac output regardless of if single waveform or an average of three waveforms were used: ρ = 0.44, 95% CI 0.18-0.63, p = 0.004, and ρ = 0.41, 95% CI 0.16-0.62, p = 0.004, respectively. CONCLUSIONS: Carotid blood flow may be a better marker of cardiac output and less subject to measurements issues than corrected carotid flow time.

A randomised crossover study to compare the cross-sectional and longitudinal approaches to ultrasound-guided peripheral venepuncture in a model.

Griffiths J, Carnegie A, Kendall R … +1 more , Madan R

Crit Ultrasound J · 2017 Dec · PMID 28374282 · Full text

BACKGROUND: Ultrasound-guided peripheral intravenous access may present an alternative to central or intraosseous access in patients with difficult peripheral veins. Using venepuncture of a phantom model as a proxy, we i... BACKGROUND: Ultrasound-guided peripheral intravenous access may present an alternative to central or intraosseous access in patients with difficult peripheral veins. Using venepuncture of a phantom model as a proxy, we investigated whether novice ultrasound users should adopt a cross-sectional or longitudinal approach when learning to access peripheral veins under ultrasound guidance. This result would inform the development of a structured training method for this procedure. METHODS: We conducted a randomised controlled trial of 30 medical students. Subjects received 35 min of training, then attempted to aspirate 1 ml of synthetic blood from a deep vein in a training model under ultrasound guidance. Subjects attempted both the cross-sectional and longitudinal approaches. Group 1 used cross-sectional first, followed by longitudinal. Group 2 used longitudinal first, then cross-sectional. We measured the time from first puncture of the model's skin to aspiration of fluid, and the number of attempts required. Subjects also reported difficulty ratings for each approach. Paired sample t-tests were used for statistical analysis. RESULTS: The mean number of attempts was 1.13 using the cross-sectional approach, compared with 1.30 using the longitudinal approach (p = 0.17). Mean time to aspiration of fluid was 45.1 s using the cross-sectional approach and 52.8 s using the longitudinal approach (p = 0.43). The mean difficulty score out of 10 was 3.97 for the cross-sectional approach and 3.93 for the longitudinal approach (p = 0.95). CONCLUSIONS: We found no significant difference in effectiveness between the cross-sectional and longitudinal approaches to ultrasound-guided venepuncture when performed on a model. We believe that both approaches should be included when teaching ultrasound-guided peripheral vascular access. To confirm which approach would be best in clinical practice, we advocate future testing of both approaches on patients.

The FAST D protocol: a simple method to rule out traumatic vascular injuries of the lower extremities.

Montorfano MA, Montorfano LM, Perez Quirante F … +3 more , Rodríguez F, Vera L, Neri L

Crit Ultrasound J · 2017 Dec · PMID 28324353 · Full text

BACKGROUND: The aim of this study is to assess the accuracy of a Fast Doppler protocol for the examination of an injured lower limb, namely 2-Point Fast Doppler (2PFD), in order to rapidly triage arterial lesions after p... BACKGROUND: The aim of this study is to assess the accuracy of a Fast Doppler protocol for the examination of an injured lower limb, namely 2-Point Fast Doppler (2PFD), in order to rapidly triage arterial lesions after penetrating trauma. METHODS: The presence of flow and the aspects of the Doppler waveform of the dorsalis pedis artery (DPA) and posterior tibial artery (PTA) of the injured lower limb (2PFD) were evaluated immediately before the execution of a standardized Color Duplex Doppler (SD) evaluation in 149 limbs of 140 patients with gunshot penetrating injuries. We considered 2PFD normal exams as the ones with triphasic patterns in both the DPA and PTA, and 2PFD pathologic exams as the ones with absent, biphasic, or monophasic flow patterns in the DPA and/or PTA. 2PFD data were then analyzed to assess accuracy variables, using SD results as matching test reference. According to the trauma center standard protocols, SD positive cases underwent also angiography and surgical exploration, whose findings were used to further match the 2PFD specificity. RESULTS: The 2PFD protocol showed a sensitivity of 100%, and a specificity of 100% compared with the SD, in the diagnostic workup of arterial injuries of the lower limbs after penetrating trauma. Furthermore, all the pathologic cases that resulted in all true positives (TP), compared with SD, were confirmed as TP also when matched with the angiography evaluation results. CONCLUSIONS: The 2PFD protocol can rapidly identify arterial flow and differentiate between normal and pathologic spectral Doppler analyses in distal arteries. The presence of the normal triphasic flows in DPA and PTA is as sensitive as the standardized Color Doppler Duplex assessment of the entire limb in ruling out arterial lesions in lower-limb penetrating trauma. The absence of flow or the presence of a biphasic or monophasic pathologic flow in DPA and PTA is pathologic and should be always followed by further investigation. 2PFD is faster and easier to perform compared with the SD approach. It could become a new first-line screening technique, both in pre-hospital and hospital critical scenarios, particularly in contexts where advanced diagnostic performance is limited by time concerns or scarce resources.

Serial lung and IVC ultrasound in the assessment of congestive heart failure.

Spevack R, Al Shukairi M, Jayaraman D … +3 more , Dankoff J, Rudski L, Lipes J

Crit Ultrasound J · 2017 Dec · PMID 28271386 · Full text

BACKGROUND: Management of congestive heart failure (CHF) is dependent on clinical assessments of volume status, which are subjective and imprecise. Point-of-care ultrasound (POCUS) is useful in the diagnosis of CHF, but... BACKGROUND: Management of congestive heart failure (CHF) is dependent on clinical assessments of volume status, which are subjective and imprecise. Point-of-care ultrasound (POCUS) is useful in the diagnosis of CHF, but how POCUS findings correlate with therapy remains unknown. This study aimed to determine whether the changes in clinical evaluation of CHF with treatment are mirrored with changes in the number of B lines on lung ultrasound (LUS) and inferior vena cava (IVC) size. In this prospective observational study, investigators performed serial clinical and ultrasound assessments within 24 h of admission (T1), day 1 in hospital (T2) and within 24 h of discharge (T3). Clinical assessments included an evaluation of the jugular venous distension (JVD), hepatojugular reflux (HJR), pulmonary rales and a clinical congestion score was calculated. Ultrasound assessment included the IVC size and collapsibility, and the number of B lines in an 8-point scan. RESULTS: Fifty consecutive patients were recruited with a mean age of 71.2 years (SD 12.7). Mean clinical congestion score on admission was 5.6 (SD 1.4) and declined significantly over time to 1.3 (0.91), as did the JVP, HJR and pulmonary rales. No significant changes were found in the IVC size between T1 [1.9 (0.65)] and T3 [2.0 (0.50)] or in the IVC collapsibility index [T1 0.3 (0.19) versus T3 0.25 (0.16)]. The mean number of B lines decreased from 11 (6.1) at T1 to 8.3 (5.5) at T3, although this decrease did not reach statistical significance. Spearman correlation between JVP and HJR versus IVC collapsibility and total B lines did not yield significant results. CONCLUSIONS: Clinical exam findings correlate over time during the management of CHF, whereas LUS and IVC results did not. The number of B lines did decrease with therapy, but did not reach statistical significance likely because the sampled population was small and had only mild heart failure. Further studies are warranted to further explore the use of lung ultrasound in this patient population.

Systematic review and meta-analysis for the use of ultrasound versus radiology in diagnosing of pneumonia.

Alzahrani SA, Al-Salamah MA, Al-Madani WH … +1 more , Elbarbary MA

Crit Ultrasound J · 2017 Dec · PMID 28244009 · Full text

BACKGROUND: Physicians are increasingly using point of care lung ultrasound (LUS) for diagnosing pneumonia, especially in critical situations as it represents relatively easy and immediately available tool. They also use... BACKGROUND: Physicians are increasingly using point of care lung ultrasound (LUS) for diagnosing pneumonia, especially in critical situations as it represents relatively easy and immediately available tool. They also used it in many associated pathological conditions such as consolidation, pleural effusion, and interstitial syndrome with some reports of more accuracy than chest X-ray. This systematic review and meta-analysis are aimed to estimate the pooled diagnostic accuracy of ultrasound for the diagnosis of pneumonia versus the standard chest radiological imaging. METHODS AND MAIN RESULTS: A systematic literature search was conducted for all published studies comparing the diagnostic accuracy of LUS against a reference Chest radiological exam (C X-ray or Chest computed Tomography CT scan), combined with clinical criteria for pneumonia in all age groups. Eligible studies were required to have a Chest X-ray and/or CT scan at the time of clinical evaluation. The authors extracted qualitative and quantitative information from eligible studies, and calculated pooled sensitivity and specificity and pooled positive/negative likelihood ratios (LR). Twenty studies containing 2513 subjects were included in this meta-analysis. The pooled estimates for lung ultrasound in the diagnosis of pneumonia were, respectively, as follows: Overall pooled sensitivity and specificity for diagnosis of pneumonia by lung ultrasound were 0.85 (0.84-0.87) and 0.93 (0.92-0.95), respectively. Overall pooled positive and negative LRs were 11.05 (3.76-32.50) and 0.08 (0.04-0.15), pooled diagnostic Odds ratio was 173.64 (38.79-777.35), and area under the pooled ROC (AUC for SROC) was 0.978. CONCLUSION: Point of care lung ultrasound is an accurate tool for the diagnosis of pneumonia. Considering being easy, readily availability, low cost, and free from radiological hazards, it can be considered as important diagnostic strategy in this condition.

Point-of-care ultrasound and Doppler ultrasound evaluation of vascular injuries in penetrating and blunt trauma.

Montorfano MA, Pla F, Vera L … +3 more , Cardillo O, Nigra SG, Montorfano LM

Crit Ultrasound J · 2017 Dec · PMID 28211004 · Full text

BACKGROUND: The aim of this study is to describe point-of-care ultrasound and Color flow Duplex Doppler characteristics of penetrating and blunt trauma-related vascular injuries of the limbs and neck. METHODS: Penetratin... BACKGROUND: The aim of this study is to describe point-of-care ultrasound and Color flow Duplex Doppler characteristics of penetrating and blunt trauma-related vascular injuries of the limbs and neck. METHODS: Penetrating and blunt trauma-related vascular injuries such as vein disruption, intimal flap, deep vein thrombosis, arterial dissection, pseudoaneurysm, and arteriovenous fistulae are discussed in this manuscript. Images of the most significant lesions of our personal clinical experience are presented to illustrate point-of-care ultrasound and Color flow Duplex Doppler ultrasound findings. RESULTS: Penetrating and blunt trauma-related vascular injuries represent a big challenge. While patients with hard signs of arterial damage must be sent immediately to surgical exploration, when there are soft signs or no clear signs of vascular injury at the physical examination, and the patient is stable, imaging investigation and observation can be useful in the diagnosis and management of these patients. Although angiography is the gold standard of the imaging methods, point-of-care ultrasound and Color flow Duplex Doppler ultrasound are widely available, cheaper, noninvasive, and faster to obtain. They can provide bedside valuable information for the identification of some vascular injuries allowing to an integrated management of the trauma patient, enriched by the use of ultrasound. CONCLUSIONS: Point-of-care ultrasound and Color flow Duplex Doppler examination are increasingly used in the decision making process of trauma-related vascular injuries.

An easy-to-build, low-budget point-of-care ultrasound simulator: from Linux to a web-based solution.

Damjanovic D, Goebel U, Fischer B … +4 more , Huth M, Breger H, Buerkle H, Schmutz A

Crit Ultrasound J · 2017 Dec · PMID 28211003 · Full text

BACKGROUND: Hands-on training in point-of-care ultrasound (POC-US) should ideally comprise bedside teaching, as well as simulated clinical scenarios. High-fidelity phantoms and portable ultrasound simulation systems are... BACKGROUND: Hands-on training in point-of-care ultrasound (POC-US) should ideally comprise bedside teaching, as well as simulated clinical scenarios. High-fidelity phantoms and portable ultrasound simulation systems are commercially available, however, at considerable costs. This limits their suitability for medical schools. A Linux-based software for Emergency Department Ultrasound Simulation (edus2TM) was developed by Kulyk and Olszynski in 2011. Its feasibility for POC-US education has been well-documented, and shows good acceptance. An important limitation to an even more widespread use of edus2, however, may be due to the need for a virtual machine for WINDOWS systems. Our aim was to adapt the original software toward an HTML-based solution, thus making it affordable and applicable in any simulation setting. METHODS: We created an HTML browser-based ultrasound simulation application, which reads the input of different sensors, triggering an ultrasound video to be displayed on a respective device. RFID tags, NFC tags, and QR Codes™ have been integrated into training phantoms or were attached to standardized patients. The RFID antenna was hidden in a mock ultrasound probe. The application is independent from the respective device. RESULTS: Our application was used successfully with different trigger/scanner combinations and mounted readily into simulated training scenarios. The application runs independently from operating systems or electronic devices. CONCLUSION: This low-cost, browser-based ultrasound simulator is easy-to-build, very adaptive, and independent from operating systems. It has the potential to facilitate POC-US training throughout the world, especially in resource-limited areas.

Erratum to: Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Marin JR, Abo AM, Arroyo AC … +24 more , Doniger SJ, Fischer JW, Rempell R, Gary B, Holmes JF, Kessler DO, Lam SHF, Levine MC, Levy JA, Murray A, Ng L, Noble VE, Ramirez-Schrempp D, Riley DC, Saul T, Shah V, Sivitz AB, Tay ET, Teng D, Chaudoin L, Tsung JW, Vieira RL, Vitberg YM, Lewiss RE

Crit Ultrasound J · 2017 Dec · PMID 28160251 · Full text

Abstract loading — click title to view on PubMed.

Point-of-care ultrasound identification of pneumatosis intestinalis in pediatric abdominal pain: a case report.

James V, Warier A, Lee KP … +1 more , Ong GY

Crit Ultrasound J · 2017 Dec · PMID 28105581 · Full text

We describe a case report of an infant with intussusception who presented to a pediatric emergency department with diarrhea and increased irritability. Pneumatosis intestinalis (intra-mural air) detected on point-of-care... We describe a case report of an infant with intussusception who presented to a pediatric emergency department with diarrhea and increased irritability. Pneumatosis intestinalis (intra-mural air) detected on point-of-care ultrasonography (but not apparent on plain abdominal radiographs) alerted the emergency physicians towards the severity of disease process.

Eliciting renal tenderness by sonopalpation in diagnosing acute pyelonephritis.

Faust JS, Tsung JW

Crit Ultrasound J · 2017 Dec · PMID 28050884 · Full text

Diagnosing acute pyelonephritis relies on the combination of historical, physical, and laboratory findings. Costovertebral angle tenderness is important, although its accuracy is unknown. Point-of-care ultrasound-guided... Diagnosing acute pyelonephritis relies on the combination of historical, physical, and laboratory findings. Costovertebral angle tenderness is important, although its accuracy is unknown. Point-of-care ultrasound-guided palpation (sonopalpation) may aid clinicians in localizing pain to discrete anatomic structures in cases of suspected acute pyelonephritis lacking classic features. We describe three low-to-moderate pre-test probability cases wherein maximal tenderness was elicited by renal sonopalpation, aiding in the diagnosis of acute pyelonephritis. In a fourth case, absence of renal tenderness to sonopalpation in a patient exhibiting typical acute pyelonephritis features led to an alternate diagnosis. Therefore, renal sonopalpation may be useful in confirming or refuting suspected cases.
← Prev Page 3 of 9 Next →

About

Frequency
Sun
Papers found
167
RSS feed
Subscribe