Searches / Critical Ultrasound Journal[JOURNAL]

Critical Ultrasound Journal[JOURNAL]

Sun 167 papers
RSS

Inferior vena cava displacement during respirophasic ultrasound imaging.

Blehar DJ, Resop D, Chin B … +2 more , Dayno M, Gaspari R

Crit Ultrasound J · 2012 Aug · PMID 22866665 · Full text

BACKGROUND: Ultrasound measurement of dynamic changes in inferior vena cava (IVC) diameter can be used to assess intravascular volume status in critically ill patients, but published studies vary in accuracy as well as r... BACKGROUND: Ultrasound measurement of dynamic changes in inferior vena cava (IVC) diameter can be used to assess intravascular volume status in critically ill patients, but published studies vary in accuracy as well as recommended diagnostic cutoffs. Part of this variability may be related to movements of the vessel relative to the transducer during the respiratory cycle which results in unintended comparison of different points of the IVC at end expiration and inspiration, possibly introducing error related to variations in normal anatomy. The objective of this study was to quantify both craniocaudal and mediolateral movements of the IVC as well as the vessel's axis of collapse during respirophasic ultrasound imaging. METHODS: Patients were enrolled from a single urban academic emergency department with ultrasound examinations performed by sonographers experienced in IVC ultrasound. The IVC was imaged from the level of the diaphragm along its entire course to its bifurcation with diameter measurements and respiratory collapse measured at a single point inferior to the confluence of the hepatic veins. While imaging the vessel in its long axis, movement in a craniocaudal direction during respiration was measured by tracking the movement of a fixed point across the field of view. Likewise, imaging the short axis of the IVC allowed for measurement of mediolateral displacement as well as the vessel's angle of collapse relative to vertical. RESULTS: Seventy patients were enrolled over a 6-month period. The average diameter of the IVC was 13.8 mm (95% CI 8.41 to 19.2 mm), with a mean respiratory collapse of 34.8% (95% CI 19.5% to 50.2%). Movement of the vessel relative to the transducer occurred in both mediolateral and craniocaudal directions. Movement was greater in the craniocaudal direction at 21.7 mm compared to the mediolateral movement at 3.9 mm (p < 0.001). Angle of collapse assessed in the transverse plane averaged 115° (95% CI 112° to 118°). CONCLUSIONS: Movement of the IVC occurs in both mediolateral and craniocaudal directions during respirophasic ultrasound imaging. Further, collapse of the vessel occurs not at true vertical (90°) but 25° off this axis. Technical approach to IVC assessment needs to be tailored to account for these factors.

Point-of-care ultrasound used to exclude penile fracture.

Ash A, Miller J, Preston D

Crit Ultrasound J · 2012 Jul · PMID 22863024 · Full text

This is a case report of a superficial penile hematoma that was difficult to distinguish clinically from a penile fracture. Such cases occur with relative frequency, and because definitive treatment is an urgent surgery,... This is a case report of a superficial penile hematoma that was difficult to distinguish clinically from a penile fracture. Such cases occur with relative frequency, and because definitive treatment is an urgent surgery, timely diagnosis is essential to avoid complications. Typical imaging modalities such as cavernosonography and magnetic resonance imaging can be invasive (cavernosonography) or time consuming (magnetic resonance imaging) and may not be readily available. Ultrasound has been used successfully in such cases, and, in this case, we used point-of-care ultrasound combined with a brief period of observation to exclude penile fracture.

Prospective application of clinician-performed lung ultrasonography during the 2009 H1N1 influenza A pandemic: distinguishing viral from bacterial pneumonia.

Tsung JW, Kessler DO, Shah VP

Crit Ultrasound J · 2012 Jul · PMID 22862998 · Full text

BACKGROUND: Emergency department visits quadrupled with the initial onset and surge during the 2009 H1N1 influenza pandemic in New York City from April to June 2009. This time period was unique in that >90% of the circul... BACKGROUND: Emergency department visits quadrupled with the initial onset and surge during the 2009 H1N1 influenza pandemic in New York City from April to June 2009. This time period was unique in that >90% of the circulating virus was surveyed to be the novel 2009 H1N1 influenza A according to the New York City Department of Health. We describe our experience using lung ultrasound in a case series of patients with respiratory symptoms requiring chest X-ray during the initial onset and surge of the 2009 H1N1 influenza pandemic. METHODS: We describe a case series of patients from a prospective observational cohort study of lung ultrasound, enrolling patients requiring chest X-ray for suspected pneumonia that coincided with the onset and surge of the 2009 H1N1 influenza pandemic. RESULTS: Twenty pandemic 2009 H1N1 influenza patients requiring chest X-ray were enrolled during this time period. Median age was 6.7 years. Lung ultrasound via modified Bedside Lung Ultrasound in Emergency protocol assisted in the identification of viral pneumonia (n = 15; 75%), viral pneumonia with superimposed bacterial pneumonia (n = 7; 35%), isolated bacterial pneumonia only (n = 1; 5%), and no findings of viral or bacterial pneumonia (n = 4; 20%) in this cohort of patients. Based on 54 observations, interobserver agreement for distinguishing viral from bacterial pneumonia using lung ultrasound was ĸ = 0.82 (0.63 to 0.99). CONCLUSIONS: Lung ultrasound may be used to distinguish viral from bacterial pneumonia. Lung ultrasound may be useful during epidemics or pandemics of acute respiratory illnesses for rapid point-of-care triage and management of patients.

Horses and Zebras: complex cardiac anatomy in a patient with out-of-hospital cardiac arrest.

Brown SM, Miller DV, Vezina D … +2 more , Dean NC, Grissom CK

Crit Ultrasound J · 2011 Apr · PMID 22022658 · Full text

This case report describes a woman presenting after out-of-hospital cardiac arrest with several cardiac anomalies, including a form fruste of Ebstein's anomaly complicated by a large tricuspid valve vegetation. On autops... This case report describes a woman presenting after out-of-hospital cardiac arrest with several cardiac anomalies, including a form fruste of Ebstein's anomaly complicated by a large tricuspid valve vegetation. On autopsy, she proved to have unstable plaques in epicardial vessels that likely caused arrhythmic sudden cardiac death, a reminder that even in the presence of rare anomalies, common things are common.

An integrated ultrasound curriculum (iUSC) for medical students: 4-year experience.

Hoppmann RA, Rao VV, Poston MB … +24 more , Howe DB, Hunt PS, Fowler SD, Paulman LE, Wells JR, Richeson NA, Catalana PV, Thomas LK, Britt Wilson L, Cook T, Riffle S, Neuffer FH, McCallum JB, Keisler BD, Brown RS, Gregg AR, Sims KM, Powell CK, Garber MD, Morrison JE, Owens WB, Carnevale KA, Jennings WR, Fletcher S

Crit Ultrasound J · 2011 Apr · PMID 21516137 · Full text

A review of the development and implementation of a 4-year medical student integrated ultrasound curriculum is presented. Multiple teaching and assessment modalities are discussed as well as results from testing and stud... A review of the development and implementation of a 4-year medical student integrated ultrasound curriculum is presented. Multiple teaching and assessment modalities are discussed as well as results from testing and student surveys. Lessons learned while establishing the curriculum are summarized. It is concluded that ultrasound is a well received, valuable teaching tool across all 4 years of medical school, and students learn ultrasound well, and they feel their ultrasound experience enhances their medical education.

Patient factors influencing the effect of surgeon-performed ultrasound on the acute abdomen.

Lindelius A, Pettersson H, Adami J … +2 more , Törngren S, Sondén A

Crit Ultrasound J · 2010 Dec · PMID 21290005 · Full text

PURPOSE: To evaluate the effect of surgeon-performed ultrasound on acute abdomen in specific patient subgroups regarding the diagnostic accuracy and further management. METHODS: Eight hundred patients attending the emerg... PURPOSE: To evaluate the effect of surgeon-performed ultrasound on acute abdomen in specific patient subgroups regarding the diagnostic accuracy and further management. METHODS: Eight hundred patients attending the emergency department at Stockholm South General Hospital, Sweden, for abdominal pain, were randomized to either receive or not receive surgeon-performed ultrasound as a complement to routine management. Patients were divided into subgroups based on patient characteristics, symptoms or first preliminary diagnosis set at the emergency department before randomization. Outcomes measured were diagnostic accuracy, admission rate and requests for further examinations. Timing of surgery was evaluated for patients with peritonitis. RESULTS: Increased diagnostic accuracy was seen in patients with body mass index > 25, elevated C-reactive protein, peritonitis, age 30-59 years and/or upper abdominal pain. Decreased need for further examinations and/or fewer admissions were seen in all groups except in patients with a preliminary diagnosis of appendicitis. Among patients with non-specific abdominal pain, admission frequency was decreased with 14% when ultrasound was used (P = 0.007). Among patients with peritonitis, requiring surgery, 61% in the ultrasound group were admitted for surgery directly from the emergency department compared to 19% in the control group. CONCLUSION: In different ways, surgeon-performed ultrasound is helpful for the majority of patients admitted to the emergency department for abdominal pain. Taking into account other shown benefits and the lack of adverse effects, we find the method worth consideration for routine implementation.

Portable ultrasound: the next generation arrives.

Ault MJ, Rosen BT

Crit Ultrasound J · 2010 Jul · PMID 21151494 · Full text

PURPOSE: A new category of handheld devices has recently emerged that are even smaller than current portable models, with their main advantages being increased portability and affordability relative to their counterparts... PURPOSE: A new category of handheld devices has recently emerged that are even smaller than current portable models, with their main advantages being increased portability and affordability relative to their counterparts. However, these new devices have not yet been thoroughly evaluated in the clinical setting. METHODS: A prospective, non-blinded, three-phase study was designed to evaluate a handheld ultrasound device as compared to a common compact ultrasound machine for the performance of paracenteses and thoracenteses on human patients. RESULTS: For the vast majority of straight-forward evaluations, the handheld device was sufficient to safely complete the procedure without further imaging. For difficult cases with smaller fluid collections or anatomic aberrations, further localization with the common compact machine continued to be useful to improve the operator's confidence in the findings. CONCLUSION: This novice handheld device represents only one of what appears to be a growing number of new ultra-portable ultrasound devices on the market. These devices represent a new and exciting form of ultrasound technology that may benefit patients and physicians in multiple venues. While they are unlikely to replace standard ultrasound devices for many of the more complex applications, their extreme portability allows for ultrasound imaging in more diverse situations that has previously been practical. Based on our limited experience, the image quality is adequate and the learning curve is reasonable. Future integration of PDA technology could further the utility of these devices and additional study will be important to further define their appropriate niche and clinical utility.