Correlation gas chromatography and two-dimensional volatility basis methods to predict gas-particle partitioning for e-cigarette aerosols.

Tian L, Woo W, Canchola A … +2 more , Chen K, Lin YH

Aerosol Sci Technol · 2024 · PMID 38774581 · Full text

E-cigarette aerosols contain a complex mixture of harmful and potentially harmful chemicals. Once released into the environment, they evolve and become new sources of indoor air pollutants that could pose a significant t... E-cigarette aerosols contain a complex mixture of harmful and potentially harmful chemicals. Once released into the environment, they evolve and become new sources of indoor air pollutants that could pose a significant threat to both users and non-users. However, current understanding of the physicochemical properties of e-cigarette aerosol constituents that govern gas-particle partitioning in the atmosphere is limited, making it difficult to estimate the health risks associated with exposure. Here, we used correlation gas chromatography (C-GC) and two-dimensional volatility basis set (2D-VBS) methods to determine the vapor pressures and volatility for commonly reported toxic and irritating e-cigarette aerosol constituents. The vapor pressures of target compounds at 298 K were estimated from the Antoine-type linear relationship between the vapor pressure of reference standards and their retention times. Our C-GC results showed an overall positive correlation (R = 0.84) with estimates using the EPI (Estimation Programs Interface) Suite. The volatility calculated by 2D-VBS correlates well with the calculated vapor pressure from both C-GC (R = 0.82) and EPI Suite (R = 0.85). The volatility distribution also indicated fresh e-cigarette aerosol constituents are mainly more volatile organic compounds. Our case study revealed that low-vapor-pressure compounds (e.g., σ-dodecalactone, γ-decalactone, and maltol) become enriched in the e-cigarette aerosols within 2 hours following vaping emissions. Overall, these findings demonstrate the applicability of the C-GC and 2D-VBS methods for determining the physiochemical properties of e-cigarette aerosol constituents, which can aid in assessing the dynamic chemical composition of e-cigarette aerosols and exposures to vaping emissions in indoor environments.

Air Change Rate and SARS-CoV-2 Exposure in Hospitals and Residences: A Meta-Analysis.

Zhang Y, Shankar SN, Vass WB … +5 more , Lednicky JA, Fan ZH, Agdas D, Makuch R, Wu CY

Aerosol Sci Technol · 2024 · PMID 38764553 · Full text

As SARS-CoV-2 swept across the globe, increased ventilation and implementation of air cleaning were emphasized by the US CDC and WHO as important strategies to reduce the risk of inhalation exposure to the virus. To asse... As SARS-CoV-2 swept across the globe, increased ventilation and implementation of air cleaning were emphasized by the US CDC and WHO as important strategies to reduce the risk of inhalation exposure to the virus. To assess whether higher ventilation and air cleaning rates lead to lower exposure risk to SARS-CoV-2, 1274 manuscripts published between April 2020 and September 2022 were screened using key words "airborne SARS-CoV-2 or "SARS-CoV-2 aerosol". Ninety-three studies involved air sampling at locations with known sources (hospitals and residences) were selected and associated data were compiled. Two metrics were used to assess exposure risk: SARS-CoV-2 concentration and SARS-CoV-2 detection rate in air samples. Locations were categorized by type (hospital or residence) and proximity to the sampling location housing the isolated/quarantined patient (primary or secondary). The results showed that hospital wards had lower airborne virus concentrations than residential isolation rooms. A negative correlation was found between airborne virus concentrations in primary-occupancy areas and air changes per hour (ACH). In hospital settings, sample positivity rates were significantly reduced in secondary-occupancy areas compared to primary-occupancy areas, but they were similar across sampling locations in residential settings. ACH and sample positivity rates were negatively correlated, though the effect was diminished when ACH values exceeded 8. While limitations associated with diverse sampling protocols exist, data considered by this meta-analysis support the notion that higher ACH may reduce exposure risks to the virus in ambient air.

The BioCascade Impactor: A novel device for direct collection of size-fractionated bioaerosols into liquid medium.

Chen Y, Chen J, Shankar SN … +6 more , Amanatidis S, Eiguren-Fernandez A, Kreisberg N, Spielman S, Lednicky JA, Wu CY

Aerosol Sci Technol · 2024 · PMID 38706712 · Full text

The ability to collect size-fractionated airborne particles that contain viable bacteria and fungi directly into liquid medium while also maintaining their viability is critical for assessing exposure risks. In this stud... The ability to collect size-fractionated airborne particles that contain viable bacteria and fungi directly into liquid medium while also maintaining their viability is critical for assessing exposure risks. In this study, we present the BioCascade impactor, a novel device designed to collect airborne particles into liquid based on their aerodynamic diameter in three sequential stages (>9.74 μm, 3.94-9.74 μm, and 1.38-3.94 μm when operated at 8.5 L/min). Aerosol samples containing microorganisms - either or , were used to evaluate the performance of the BioCascade (BC) paired with either the VIable Virus Aerosol Sampler (VIVAS) or a gelatin filter (GF) as stage 4 to collect particles <1.38 μm. Stages 2 and 3 collected the largest fractions of viable when paired with VIVAS (0.468) and GF (0.519), respectively. Stage 3 collected the largest fraction of viable particles in both BC+VIVAS (0.791) and BC+GF (0.950) configurations. The distribution function of viable microorganisms was consistent with the size distributions measured by the Aerodynamic Particle Sizer. Testing with both bioaerosol species confirmed no internal loss and no re-aerosolization occurred within the BC. Irrespective of the bioaerosol tested, stages 1, 3 and 4 maintained ≥80% of viability, while stage 2 maintained only 37% and 73% of viable and , respectively. The low viability that occurred in stage 2 warrants further investigation. Our work shows that the BC can efficiently size-classify and collect bioaerosols without re-aerosolization and effectively maintain the viability of collected microorganisms.

Impact of test methodology on the efficacy of triethylene glycol (Grignard Pure) against bacteriophage MS2.

Ratliff KM, Oudejans L, Archer J … +7 more , Calfee W, Gilberry JU, Hook DA, Schoppman WE, Yaga RW, Brooks L, Ryan S

Aerosol Sci Technol · 2023 Nov · PMID 38268721 · Full text

The COVID-19 pandemic has raised interest in using chemical air treatments as part of a strategy to reduce the risk of disease transmission, but more information is needed to characterize their efficacy at scales transla... The COVID-19 pandemic has raised interest in using chemical air treatments as part of a strategy to reduce the risk of disease transmission, but more information is needed to characterize their efficacy at scales translatable to applied settings and to develop standardized test methods for characterizing the performance of these products. Grignard Pure, a triethylene glycol (TEG) active ingredient air treatment, was evaluated using two different test protocols in a large bioaerosol test chamber and observed to inactivate bacteriophage MS2 in air (up to 99.9% at 90 min) and on surfaces (up to 99% at 90 min) at a concentration of approximately 1.2 - 1.5 mg/m. Introducing bioaerosol into a TEG-charged chamber led to overall greater reductions compared to when TEG was introduced into a bioaerosol-charged chamber, although the differences in efficacy against airborne MS2 were only significant in the first 15 min. Time-matched control conditions (no TEG present) and replicate tests for each condition were essential for characterizing treatment efficacy. These findings suggest that chemical air treatments could be effective in reducing the air and surface concentrations of infectious pathogens in occupied spaces, although standard methods are needed for evaluating their efficacy and comparing results across studies. The potential health impacts of chronic exposure to chemicals should also be considered, but those were not evaluated here.

Impact of Chemical Speciation Network method changes on time series ion and carbon species concentrations.

Kaur K, Krall JR, Ivey C … +2 more , Holmes HA, Kelly KE

Aerosol Sci Technol · 2024 · PMID 40242604 · Full text

Numerous studies rely on long-term PM speciation data from the EPA's Chemical Speciation Network (CSN), for example, to estimate health impacts or investigate the sources and transport of PM pollution. These studies rely... Numerous studies rely on long-term PM speciation data from the EPA's Chemical Speciation Network (CSN), for example, to estimate health impacts or investigate the sources and transport of PM pollution. These studies rely on consistent, long-term time series measurements of PM species to draw conclusions about PM emissions sources and their health impacts. However, changes in contractors and associated methodological changes in 2015 and 2018 led to disruptions in the consistency of the CSN data, specifically, concentration discontinuities in the CSN time series for ions and elemental carbon (EC) from November 2015 to September 2018 and from October 2018 onward, respectively. To address the impact of these changes on downstream air quality and health analyses, this study developed correction factors by comparing collocated CSN measurements to measurements from the Interagency Monitoring of Protected Visual Environment (IMPROVE) network, which used consistent instrumentation and contractors throughout the study period. These correction factors reduced the discontinuities in the ions and EC concentration time series data, which could be critical for time series source apportionment receptor modeling, air pollution policy and accountability investigations, and health effect studies.

Airborne bacteria in institutional and commercial buildings in Korea: characterization with 16S rRNA gene sequencing and association with environmental conditions.

Kim YJ, Lee BG, Shim JE … +3 more , Lee H, Park JH, Yeo MK

Aerosol Sci Technol · 2024 · PMID 40125263 · Full text

Information on microorganisms in indoor air of various institutional and commercial buildings has significant value in a public health management perspective. However, there is a lack of prior research comparing indoor a... Information on microorganisms in indoor air of various institutional and commercial buildings has significant value in a public health management perspective. However, there is a lack of prior research comparing indoor airborne microbiota across different categories of those buildings. We characterized indoor airborne bacteria in 10 buildings (two for each of five categories: train station, parking garage, mart, public library, and daycare center) during summer and winter. The 16S rRNA gene in the bacterial gDNA extracted from samples was quantified using quantitative real-time polymerase chain reaction and sequenced with the Illumina MiSeq platform for characterizing community composition. We collected information on temperature, relative humidity, CO concentration, and particulate matter (PM) concentrations by particle size (<1μm, 1-2.5μm, 2.5-10μm) indoors. We performed a multivariate regression analysis to identify factors influencing bacterial quantity and Permutational Multivariate Analysis of Variance (PERMANOVA) to determine factors affecting cluster dissimilarity. We found that bacterial concentration was significantly (-values < 0.05) associated with season and CO concentration. The PERMANOVA analyses showed the significant (-values < 0.05) associations of bacterial cluster dissimilarity with season, building category, and CO. Our study indicated that the season, and CO concentrations may be important factors associated with the indoor airborne bacterial concentration and composition. Building category and usage appeared to significantly influence the bacterial community composition but not the concentration. Our study may provide basic data on bacterial community composition and their concentration that are needed for properly managing microbial exposures in occupants or customers of the studied institutional and commercial buildings.

Detection and isolation of infectious SARS-CoV-2 omicron subvariants collected from residential settings.

Vass WB, Shankar SN, Lednicky JA … +12 more , Yang Y, Manzanas C, Zhang Y, Boyette J, Chen J, Chen Y, Shirkhani A, Washeem M, Fan ZH, Eiguren-Fernandez A, Jutla A, Wu CY

Aerosol Sci Technol · 2023 · PMID 38143528 · Full text

Airborne transmission of infectious (viable) SARS-CoV-2 is increasingly accepted as the primary manner by which the virus is spread from person to person. Risk of exposure to airborne virus is higher in enclosed and poor... Airborne transmission of infectious (viable) SARS-CoV-2 is increasingly accepted as the primary manner by which the virus is spread from person to person. Risk of exposure to airborne virus is higher in enclosed and poorly ventilated spaces. We present a study focused on air sampling within residences occupied by individuals with COVID-19. Air samplers (BioSpot-VIVAS, VIVAS, and BC-251) were positioned in primary- and secondary-occupancy regions in seven homes. Swab samples were collected from high-touch surfaces. Isolation of SARS-CoV-2 was attempted for samples with virus detectable by RT-qPCR. Viable virus was quantified by plaque assay, and complete virus genome sequences were obtained for selected samples from each sampling day. SARS-CoV-2 was detected in 24 of 125 samples (19.2%) by RT-qPCR and isolated from 14 (11.2%) in cell cultures. It was detected in 80.9% (17/21) and cultured from 61.9% (13/21) of air samples collected using water condensation samplers, compared to swab samples which had a RT-qPCR detection rate of 10.5% (4/38) and virus isolation rate of 2.63% (1/38). No statistically significant differences existed in the likelihood of virus detection by RT-qPCR or amount of infectious virus in the air between areas of primary and secondary occupancy within residences. Our work provides information about the presence of SARS-CoV-2 in the air within homes of individuals with COVID-19. Information herein can help individuals make informed decisions about personal exposure risks when sharing indoor spaces with infected individuals isolating at home and further inform health departments and the public about SARS-CoV-2 exposure risks within residences.

Understanding the influence of atomizing power on electronic cigarette aerosol size and inhalation dose estimation.

Lee J, Su WC, Han I

Aerosol Sci Technol · 2023 · PMID 37997608 · Full text

Although many studies have estimated the inhalation dose of aerosols emitted from electronic cigarettes (e-cigs), the association between the atomizing power and inhalation dose of e-cig aerosols has not been fully exami... Although many studies have estimated the inhalation dose of aerosols emitted from electronic cigarettes (e-cigs), the association between the atomizing power and inhalation dose of e-cig aerosols has not been fully examined. The aim of this study was to determine the mass and inhalation doses of e-cig aerosols and their association with the atomizing power of vaping devices. Size-segregated aerosol masses were collected using an 11-stage cascade impactor and the deposition dose in the human respiratory tract was estimated using the size-segregated aerosol mass. The results showed that an increase in atomizing power was positively associated with the amount of aerosol mass generated (p-value < 0.001). The mass median aerodynamic diameter and mass mean diameter of aerosol were 0.91 μm and 0.84 μm, respectively. The average deposition fractions of aerosols in the head airway, tracheobronchial region, and alveolar region were 67.2, 6.2, and 26.6%, respectively. In conclusion, vaping with a higher atomizing power increases the e-cig aerosol inhalation dose in the airway.

Influence of puff topographies on e-liquid heating temperature, emission characteristics and modeled lung deposition of Puff Bar.

Ranpara A, Stefaniak AB, Fernandez E … +3 more , Bowers LN, Arnold ED, LeBouf RF

Aerosol Sci Technol · 2023 Mar · PMID 37969359 · Full text

Puff Bar, one of the latest designs of e-cigarettes, heats a mixture of liquid using a battery-powered coil at certain temperatures to emit aerosol. This study presents a mass-based characterization of emissions from sev... Puff Bar, one of the latest designs of e-cigarettes, heats a mixture of liquid using a battery-powered coil at certain temperatures to emit aerosol. This study presents a mass-based characterization of emissions from seven flavors of Puff Bar devices by aerosolizing with three puff topographies [(puff volume: 55 < 65 < 75-mL) within 4-seconds at 30-seconds interval]. We evaluated the effects of puff topographies on heating temperatures; characterized particles using a cascade impactor; and measured volatile carbonyl compounds (VCCs). Modeled dosimetry and calculated mass median aerodynamic diameters (MMADs) were used to estimate regional, total respiratory deposition of the inhaled aerosol and exhaled fractions that could pose secondhand exposure risk. Temperatures of Puff Bar e-liquids increased with increasing puff volumes: 55mL (116.6 °C), 65 mL (128.3 °C), and 75mL (168.9 °C). Flavor types significantly influenced MMADs, total mass of particles, and VCCs (μg/puff: 2.15-2.30) in Puff Bar emissions (p < 0.05). Increasing puff volume (mL:55 < 65 < 75) significantly increased total mass (mg/puff: 4.6 < 5.6 < 6.2) of particles without substantially changing MMADs (~1μm:1.02~0.99~0.98). Aerosol emissions were estimated to deposit in the pulmonary region of e-cigarette user (41-44%), which could have toxicological importance. More than 2/3 (67-77%) of inhaled particles were estimated to be exhaled by users, which could affect bystanders. The VCCs measured contained carcinogens-formaldehyde (29.6%) and acetaldehyde (16.4%)-as well as respiratory irritants: acetone (23.9%), isovaleraldehyde (14.5%), and acrolein (4.9%). As Puff Bar emissions contain respirable particles and harmful chemicals, efforts should be made to minimize exposures, especially in indoor settings where people (including vulnerable populations) spend most of their life-time.

NanoSpot collector for aerosol sample collection for direct microscopy and spectroscopy analysis.

Zervaki O, Stump B, Keady P … +2 more , Dionysiou DD, Kulkarni P

Aerosol Sci Technol · 2023 Jan · PMID 37284690 · Full text

We describe design and characterization of an aerosol NanoSpot collector, designed for collection of airborne particles on a microscopy substrate for direct electron and optical microscopy, and laser spectroscopy analysi... We describe design and characterization of an aerosol NanoSpot collector, designed for collection of airborne particles on a microscopy substrate for direct electron and optical microscopy, and laser spectroscopy analysis. The collector implements a water-based, laminar-flow, condensation growth technique, followed by impaction onto an optical/electron microscopy substrate or a transmission electron microscopy grid for direct analysis. The compact design employs three parallel growth tubes allowing a sampling flow rate of 1.2 L min. Each growth tube consists of three-temperature regions, for controlling the vapor saturation profile and exit dew point. Following the droplet growth, the three streams merge into one flow and a converging nozzle enhances focusing of grown droplets into a tight beam, prior to their final impaction on the warm surface of the collection substrate. Experiments were conducted for the acquisition of the size-dependent collection efficiency and the aerosol concentration effect on the NanoSpot collector. Particles as small as 7 nm were activated and collected on the electron microscopy stub. The collected particle samples were analyzed using electron microscopy and Raman spectroscopy for the acquisition of the particle spatial distribution, the spot sample uniformity, and the analyte concentration. A spot deposit of approximately 0.7-mm diameter is formed for particles over a broad particle diameter range, for effective coupling with microscopic and spectroscopic analysis. Finally, the NanoSpot collector's analytical measurement sensitivity for laser Raman analysis and counting statistics for fiber count measurement using optical microscopy were calculated and were compared with those of the conventional aerosol sampling methods.

Transmission of SARS-CoV-2 in the workplace: Key findings from a rapid review of the literature.

Cox J, Christensen B, Burton N … +4 more , Dunn KH, Finnegan M, Ruess A, Estill C

Aerosol Sci Technol · 2023 Jan · PMID 37213938 · Full text

At the beginning of the COVID-19 pandemic, the primary route of transmission of the SARS-CoV-2 virus was not well understood. Research gathered from other respiratory infectious diseases, including other coronaviruses, w... At the beginning of the COVID-19 pandemic, the primary route of transmission of the SARS-CoV-2 virus was not well understood. Research gathered from other respiratory infectious diseases, including other coronaviruses, was the basis for the initial perceptions for transmission of SARS-CoV-2. To better understand transmission of SARS-CoV-2, a rapid literature review was conducted from literature generated March 19, 2020, through September 23, 2021. 18,616 unique results were identified from literature databases and screened. Of these, 279 key articles were reviewed and abstracted covering critical topics such as environmental/workplace monitoring, sampling and analytical method evaluation, and the ability of the virus to remain intact and infectious during sampling. This paper describes the results of the rapid literature review, which evaluated pathways that contribute to transmission as well as the strengths and limitations of current sampling approaches. This review also evaluates how different factors, including environmental conditions and surface characteristics, could impact the transmission potential of SARS-CoV-2. A continual rapid review in the midst of a pandemic proved particularly useful for quickly understanding the transmission parameters of the virus and enabled us to comprehensively assess literature, respond to workplace questions, and evaluate our understanding as the science evolved. Air and surface sampling with the accompanying analytical methods were not generally effective in recovering SARS-CoV-2 viable virus or RNA in many likely contaminated environments. In light of these findings, the development of validated sampling and analysis methods is critical for determining worker exposure to SARS-CoV-2 and to assess the impact of mitigation efforts.

Constant vs. cyclic flow when testing face masks and respirators as source control devices for simulated respiratory aerosols.

Lindsley WG, Blachere FM, Derk RC … +5 more , Boots T, Duling MG, Boutin B, Beezhold DH, Noti JD

Aerosol Sci Technol · 2023 Jan · PMID 37206373

SARS-CoV-2 spreads by infectious aerosols and droplets from the respiratory tract. Masks and respirators can reduce the transmission of infectious respiratory diseases by collecting these aerosols at the source. The abil... SARS-CoV-2 spreads by infectious aerosols and droplets from the respiratory tract. Masks and respirators can reduce the transmission of infectious respiratory diseases by collecting these aerosols at the source. The ability of source control devices to block aerosols can be tested by expelling an aerosol through a headform using constant airflows, which are simpler, or cyclic airflows, which are more realistic but require more complex methods. Experiments with respirators found that using cyclic vs. constant flows affected the amount of aerosol inhaled, but similar comparisons have not been made for source control devices with exhaled aerosols. We measured the collection efficiencies for exhaled aerosols for two cloth masks, two medical masks with and without an elastic mask brace, a neck gaiter, and an N95 filtering facepiece respirator using 15 L/min and 85 L/min constant and cyclic flows and a headform with pliable skin. The collection efficiencies for the 15 L/min cyclic flow, 15 L/min constant flow, and 85 L/min constant flow were not significantly different in most cases. The apparent collection efficiencies for the 85 L/min cyclic flow were artificially increased by rebreathing and refiltration of the aerosol from the collection chamber. The collection efficiencies correlated well with the fit factors ( > 0.95) but not the filtration efficiencies ( < 0.54). Our results suggest that the aerosol collection efficiency measurements of source control devices are comparable when testing the devices using either constant or cyclic airflows and that the potential for aerosol rebreathing must be considered when conducting experiments.

Development of air purifier operation guidelines using grey box models for the concentrations of particulate matter in elementary school classrooms.

Park S, Song D, Jo YM … +3 more , Park JH, Lee TJ, Koo J

Aerosol Sci Technol · 2023 · PMID 38799734 · Full text

Considering the hazardous effects of particulate matter (PM) exposure on students and teachers and the high PM concentration issue in South Korea, air purifiers have recently been installed in most classrooms to improve... Considering the hazardous effects of particulate matter (PM) exposure on students and teachers and the high PM concentration issue in South Korea, air purifiers have recently been installed in most classrooms to improve air quality. However, some on-site challenges, such as operational costs and noise, have been issues with the continuous operation of air purifiers. Therefore, a guideline is needed to dynamically predict the indoor PM concentration based on the changes in outdoor PM concentration and activate the air purifiers only when necessary. This study develops a grey-box model that uses measured data and physical differential equations to perform the given objective and verifies its accuracy using ASTM D5157. Modeling and analysis results have obtained information that can form the basis for developing guidelines to address PM issues in schools: The air purifier should be operated during periods where the predicted values exceed the limit in closed windows and the air purifier is not operating. It was also confirmed that the need for the operation of the air purifier varies between schools and classrooms under the same outdoor PM concentration. Indoor PM concentration increased significantly after students' simultaneous mass movement, necessitating air purifiers' operation before and after the events. The prefilter of the heater also aided in the removal of coarse PM. Additionally, the limitations and future development directions of the model were discussed.

Efficacy of Aerosol Reduction Measures for Dental Aerosol Generating Procedures.

He Z, Gao Q, Henley A … +5 more , Khatchadourian Z, Somerville W, Wiseman M, Mongeau L, Tamimi F

Aerosol Sci Technol · 2022 · PMID 36311996 · Full text

Aerosol particles generated by dental procedures could facilitate the transmission of infectious diseases and contain carcinogen particles. Such particles can penetrate common surgical masks and reach the lungs, leading... Aerosol particles generated by dental procedures could facilitate the transmission of infectious diseases and contain carcinogen particles. Such particles can penetrate common surgical masks and reach the lungs, leading to increased risk for dental care professionals. However, the risk of inhaling contaminated aerosol and the effectiveness of aerosol reduction measures in dental offices remain unclear. The present study aimed to quantify aerosols produced by drilling and scaling procedures and to evaluate present recommendations for aerosol reduction. The concentration of aerosol particles released from the mock scaling and drilling procedures on dental mannequin were measured using a TSI Optical Particle Sizer (OPS 3330) during 15-min sessions carried out in a single-patient examination room. Using a drilling procedure as the aerosol source, the aerosol reduction performance of two types of high-volume evacuators (HVEs) and a commercial off-the-shelf air purifier was evaluated in a simulated clinical setting. Using either HVEs or the air purifier individually reduced the aerosol accumulated over the course of a 15-minutes drilling procedure at a reduction rate of 94.8 to 97.6%. Using both measures simultaneously raised the reduction rate to 99.6%. The results show that existing HVEs can effectively reduce aerosol concentration generated by a drilling procedure and can be further improved by using an air purifier. Following current regulatory guidelines can ensure a low risk of inhaling contaminated aerosol for dentists, assistants, and patients.

Lithium-ion battery explosion aerosols: Morphology and elemental composition.

Barone TL, Dubaniewicz TH, Friend SA … +3 more , Zlochower IA, Bugarski AD, Rayyan NS

Aerosol Sci Technol · 2021 Jul · PMID 35923215 · Full text

Aerosols emitted by the explosion of lithium-ion batteries were characterized to assess potential exposures. The explosions were initiated by activating thermal runaway in three commercial batteries: (1) lithium nickel m... Aerosols emitted by the explosion of lithium-ion batteries were characterized to assess potential exposures. The explosions were initiated by activating thermal runaway in three commercial batteries: (1) lithium nickel manganese cobalt oxide (NMC), (2) lithiumiron phosphate (LFP), and (3) lithium titanate oxide (LTO). Post-explosion aerosols were collected on anodisc filters and analyzed by scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS). The SEM and EDS analyses showed that aerosol morphologies and compositions were comparable to individual grains within the original battery materials for the NMC cell, which points to the fracture and ejection of the original battery components during the explosion. In contrast, the LFP cell emitted carbonaceous cenospheres, which suggests aerosol formation by the decomposition of organics within molten microspheres. LTO explosion aerosols showed characteristics of both types of emissions. The abundance of elements from the anode, cathode, and separator in respirable aerosols underscored the need for the selection of low-toxicity battery materials due to potential exposures in the event of battery thermal runaway.

Laboratory study of physical barrier efficiency for worker protection against SARS-CoV-2 while standing or sitting.

Bartels J, Estill CF, Chen IC … +1 more , Neu D

Aerosol Sci Technol · 2022 Jan · PMID 35677842 · Full text

Transparent barriers were installed as a response to the SARS-COV-2 pandemic in many customer-facing industries. Transparent barriers are an engineering control that intercept particles traveling between customers and wo... Transparent barriers were installed as a response to the SARS-COV-2 pandemic in many customer-facing industries. Transparent barriers are an engineering control that intercept particles traveling between customers and workers. Information on the effectiveness of these barriers against aerosols is limited. In this study, a cough simulator was used to represent a cough from a customer. Two optical particle counters were used (one on each side of the barrier, labeled customer and worker) to determine the number of particles that migrated around a transparent barrier. Ten configurations were tested with six replicates for both sitting and standing scenarios, representing nail salons and grocery stores, respectively. Barrier efficiency was calculated using a ratio of the particle count results (customer/worker). Barriers had better efficiency (up to 93%) when its top was 9 to 39 cm above cough height and its width was at least 91 cm. Barriers that extended 91 cm above table height for both scenarios blocked 71% or more of the particles between 0.35-0.725 μm and 68% for particles between 1 to 3 μm. A barrier that blocked an initial cough was effective at reducing particle counts. While the width of the barriers was not as significant as the height in determining barrier efficiency it is important that a barrier be placed where interactions between customers and workers are most frequent. Bystander exposure was not taken into consideration along with other limitations.

Experimental verification of principal losses in a regulatory particulate matter emissions sampling system for aircraft turbine engines.

Kittelson DB, Swanson J, Aldridge M … +23 more , Giannelli RA, Kinsey JS, Stevens JA, Liscinsky DS, Hagen D, Leggett C, Stephens K, Hoffman B, Howard R, Frazee RW, Silvis W, McArthur T, Lobo P, Achterberg S, Trueblood M, Thomson K, Wolff L, Cerully K, Onasch T, Miake-Lye R, Freedman A, Bachalo W, Payne G

Aerosol Sci Technol · 2021 Nov · PMID 35602286 · Full text

A sampling system for measuring emissions of nonvolatile particulate matter (nvPM) from aircraft gas turbine engines has been developed to replace the use of smoke number and is used for international regulatory purposes... A sampling system for measuring emissions of nonvolatile particulate matter (nvPM) from aircraft gas turbine engines has been developed to replace the use of smoke number and is used for international regulatory purposes. This sampling system can be up to 35 m in length. The sampling system length in addition to the volatile particle remover (VPR) and other sampling system components lead to substantial particle losses, which are a function of the particle size distribution, ranging from 50 to 90% for particle number concentrations and 10-50% for particle mass concentrations. The particle size distribution is dependent on engine technology, operating point, and fuel composition. Any nvPM emissions measurement bias caused by the sampling system will lead to unrepresentative emissions measurements which limit the method as a universal metric. Hence, a method to estimate size dependent sampling system losses using the system parameters and the measured mass and number concentrations was also developed (SAE 2017; SAE 2019). An assessment of the particle losses in two principal components used in ARP6481 (SAE 2019) was conducted during the VAriable Response In Aircraft nvPM Testing (VARIAnT) 2 campaign. Measurements were made on the 25-meter sample line portion of the system using multiple, well characterized particle sizing instruments to obtain the penetration efficiencies. An agreement of ± 15% was obtained between the measured and the ARP6481 method penetrations for the 25-meter sample line portion of the system. Measurements of VPR penetration efficiency were also made to verify its performance for aviation nvPM number. The research also demonstrated the difficulty of making system loss measurements and substantiates the E-31 decision to predict rather than measure system losses.

Laboratory Determination of Gravimetric Correction Factors for Real-time Area Measurements of Electronic Cigarette Aerosols.

Sousan S, Pender J, Streuber D … +3 more , Haley M, Shingleton W, Soule E

Aerosol Sci Technol · 2022 · PMID 35527743 · Full text

Research on secondhand electronic cigarette (ECIG) aerosol exposure using aerosol monitors has demonstrated that ECIG use can generate high concentrations of particulate matter (PM) and impact indoor air quality. However... Research on secondhand electronic cigarette (ECIG) aerosol exposure using aerosol monitors has demonstrated that ECIG use can generate high concentrations of particulate matter (PM) and impact indoor air quality. However, quantifying indoor air PM concentrations using real-time optical monitors with on-site calibration specifically for different PM exposures has not been established. Therefore, the ECIG aerosol filter correction factors were calculated for different PM sizes (PM, PM, and PM) and different aerosol optical monitors, the MiniWRAS, pDR, and SidePak. ECIG aerosol generation was achieved using five ECIGs representing three ECIG types, disposable, pod-mod, and box mod. The aerosol size distribution by mass was measured for the five ECIGs during PM generation. Compared to the discrete filter measurements, the MiniWRAS performed the best when the concentrations were low, followed by the pDR and SidePak. The average PM concentrations and correction factor ranges for the different ECIGs were 323-1,775 μg/m and 0.64-6.01 for the MiniWRAS, 1,388-13,365 μg/m and 0.41-0.80 for the pDR, and 4,632-55,339 μg/m and 0.13-0.20 for the SidePak, respectively. The mass median diameter ranged from 0.41 and 0.62 μm, and most particles generated from the ECIGs were smaller than 1 μm. This study demonstrates that aerosol size distribution varies between ECIGs. Likewise, the correction factors developed for the real-time aerosol monitors are specific to the ECIG used. Thus, these data can help improve ECIG aerosol exposure measurement accuracy.

Comparison of the survival of different isolates of SARS-CoV-2 in evaporating aerosols.

Dabisch PA, Wood SP, Holland BP … +4 more , Boydston JA, Beck KE, Green B, Biryukov J

Aerosol Sci Technol · 2022 · PMID 38075547 · Full text

Numerous variants of SARS-CoV-2 with increased transmissibility have emerged over the course of the pandemic. Potential explanations for the increased transmissibility of these variants include increased shedding from in... Numerous variants of SARS-CoV-2 with increased transmissibility have emerged over the course of the pandemic. Potential explanations for the increased transmissibility of these variants include increased shedding from infected individuals, increased environmental stability, and/or a lower infectious dose. Upon exhalation of a respiratory particle into the environment, water present in the particle is rapidly lost through evaporation, resulting in a decrease in particle size. The aim of the present study was to compare the losses of infectivity of different isolates of SARS-CoV-2 during the rapid evaporation of aerosol particles that occurs immediately post-generation to assess if there are differences suggestive of increased survival, and ultimately greater transmissibility, for more recent variants. Losses of infectivity of several isolates of SARS-CoV-2 suspended in viral culture media were assessed following aerosolization and evaporation in a flowing chamber. The results demonstrate that losses of infectivity measured post-evaporation were similar for three different isolates of SARS-CoV-2, including isolates from the more recent Delta and Omicron lineages. The average loss in infectivity across all three isolates was 61 ± 15% (-0.46 ± 0.17 log TCID/L-air) at a relative humidity <30%. These results, together with those from several previous studies, suggest that it is unlikely that an increase in environmental stability contributes to the observed increases in transmissibility observed with more recent variants of SARS-CoV-2.

Development and initial testing of an active low-power, ferroelectric film-based bioaerosol sampler.

Grogan SNCM, Han TT, Mainelis G

Aerosol Sci Technol · 2022 · PMID 37168518 · Full text

This article introduces REAS (Rutgers Electrostatic Active Sampler), a new active bioaerosol sampler using permanently polarized ferroelectric film (e.g., PVDF) to capture charge-carrying bioaerosol particles. While REAS... This article introduces REAS (Rutgers Electrostatic Active Sampler), a new active bioaerosol sampler using permanently polarized ferroelectric film (e.g., PVDF) to capture charge-carrying bioaerosol particles. While REAS operates on an electrostatic collection principle, due to its unique materials and design, it does not require external power to charge incoming particles or to create an electrostatic collection field. The sampler consists of a polarized film wound in a spiral configuration with oppositely polarized film sides positioned 2.25 mm apart. The film and its holder are inserted into a 3D-printed housing cylinder to connect to a pump. The device has an open channel design, creating virtually no pressure drop, which allows for longer sampling times on the same battery charge compared to filter samplers. When REAS was tested in different field environments, the physical collection efficiency ranged from 19 ± 2% in a laboratory environment at 1 L/min to 41 ± 0.1% in residence at 0.1 L/min. When REAS was used to capture culturable bacteria and fungi over a 24-hr period, the concentrations determined by REAS were not different from those determined by an Institute of Medicine sampler (IOM, SKC, Inc.). The concentrations determined by both samplers were lower than those measured by a SAS Super 180 Sampler (SAS, Bioscience International), except for outdoor fungi. However, the SAS was used as a grab sampler to avoid overloading or desiccating the plates, while both REAS and IOM continuously sampled for 24 hrs. Further studies will explore improvements to the REAS sample elution protocols.