Aerosol Sci Technol
· 2016 Aug · PMID 28638174
·
Full text
A sensitive, field-portable microplasma spectroscopy method has been developed for real-time measurement of carbon nanomaterials. The method involves microconcentration of aerosol on a microelectrode tip for subsequent a...A sensitive, field-portable microplasma spectroscopy method has been developed for real-time measurement of carbon nanomaterials. The method involves microconcentration of aerosol on a microelectrode tip for subsequent analysis for atomic carbon using laser-induced breakdown spectroscopy (LIBS) or spark emission spectroscopy (SES). The spark-induced microplasma was characterized by measuring the excitation temperature (15,000 - 35,000 K), electron density (1.0 × 10 - 2.2 × 10 cm), and spectral responses as functions of time and interelectrode distance. The system was calibrated and detection limits were determined for total atomic carbon (TAC) using a carbon emission line at 247.856 nm (C I) for various carbonaceous materials including sucrose, EDTA, caffeine, sodium carbonate, carbon black, and carbon nanotubes. The limit of detection for total atomic carbon was 1.61 ng, equivalent to 238 ng m when sampling at 1.5 L min for 5 min. To improve the selectivity for carbon nanomaterials, which consist of elemental carbon (EC), the cathode was heated to 300 °C to reduce the contribution of organic carbon to the total atomic carbon. Measurements of carbon nanotube aerosol at elevated electrode temperature showed improved selectivity to elemental carbon and compared well with the measurements from thermal optical method (NIOSH Method 5040). The study shows that the SES method to be an excellent candidate for development as a low-cost, hand-portable, real-time instrument for measurement of carbonaceous aerosols and nanomaterials.
Aerosol Sci Technol
· 2017 · PMID 28435179
·
Full text
Composite nanoparticles find application in catalysis, drug delivery, and energy storage and require increasingly fine control of their physical properties and composition. While composite nanoparticles have been widely...Composite nanoparticles find application in catalysis, drug delivery, and energy storage and require increasingly fine control of their physical properties and composition. While composite nanoparticles have been widely synthesized and characterized, little work has systematically correlated the initial concentration of precursors and the final composition of flame synthesized composite nanoparticles. This relationship is explored in a diffusion flame aerosol reactor by coupling a scanning mobility particle sizer (SMPS) with an inductively coupled plasma optical emission spectrometer (ICP-OES). A framework for studying the relationship between the initial precursor concentrations of different elements and the final nanoparticle composition is explored. The size-resolved elemental composition was measured by directly injecting size-selected fractions of aggregated magnetite and silicon dioxide composite nanoparticles into the ICP-OES plasma. This work showed a correlation between precursor molar ratio and the measured elemental ratio in the mobility size range of 50 to 140 nm. Building on previous work studying size resolved elemental composition of engineered nanoparticles, the analysis is extended to flame synthesized composite nanoparticle aggregates in this work.
Krug JD, Dart A, Witherspoon CL
… +4 more, Gilberry J, Malloy Q, Kaushik S, Vanderpool RW
Aerosol Sci Technol
· 2017 Apr · PMID 32025079
·
Full text
Under the National Ambient Air Quality Standard (NAAQS) for airborne lead, measurements are conducted by means of a high-volume total suspended particulate matter (Hi-Vol TSP) sampler. In the decade between 1973 and 1983...Under the National Ambient Air Quality Standard (NAAQS) for airborne lead, measurements are conducted by means of a high-volume total suspended particulate matter (Hi-Vol TSP) sampler. In the decade between 1973 and 1983, there were 12 publications that explored the sampling characteristics and effectiveness of the Hi-Vol TSP, yet there persists uncertainty regarding its performance. This article presents an overview of the existing literature on the performance of the Hi-Vol TSP, and identifies the reported sampler effectiveness with respect to four factors: particle size (reported effectiveness of 7%-100%), wind speed (-36% to 100%), sampler orientation (7%-100%), and operational state (107%-140%). Effectiveness of the Hi-Vol TSP was evaluated with a solid, polydisperse aerosol in a controlled wind tunnel setting. Isokinetic samplers were deployed alongside the Hi-Vol TSP to investigate three wind speeds (2, 8, and 24 km h), three sampler orientations (0°, 45°, 90°), and two operational states (on, off) for aerosols with aerodynamic diameters from 5 to 35 μm. Results indicate that particle diameter was the largest determining factor of effectiveness followed by wind speed. Orientation of the sampler did not have a significant effect at 2 and 8 km h but did at 24 km h. In a passive state, the Hi-Vol TSP was collected between 1% and 7% of available aerosol depending on particle size and wind speed. Results of this research do not invalidate results of previous studies but rather contribute to our overall understanding of the Hi-Vol TSP's size-selective performance. While results generally agreed with previous studies, the Hi-Vol TSP was found to exhibit less dependence on these four factors than previously reported.
Baassiri M, Talih S, Salman R
… +5 more, Karaoghlanian N, Saleh R, El Hage R, Saliba N, Shihadeh A
Aerosol Sci Technol
· 2017 · PMID 32863527
·
Full text
Electronic cigarettes (ECIGs) heat and vaporize a liquid mixture to produce an inhalable aerosol that can deliver nicotine to the user. The liquid mixture is typically composed of propylene glycol (PG) and vegetable glyc...Electronic cigarettes (ECIGs) heat and vaporize a liquid mixture to produce an inhalable aerosol that can deliver nicotine to the user. The liquid mixture is typically composed of propylene glycol (PG) and vegetable glycerin (VG), in which are dissolved trace quantities of flavorants and, usually, nicotine. Due to their different chemical and thermodynamic properties, the proportions of PG and VG in the liquid solution may affect nicotine delivery and user sensory experience. In social media and popular culture, greater PG fraction is associated with greater "throat-hit", a sensation that has been attributed in cigarette smokers to increased presence of vapor-phase nicotine. VG, on the other hand, is associated with thicker and larger exhaled "clouds". In this study, we aim to investigate how PG/VG ratio influences variables that relate to nicotine delivery and plume visibility. Aerosols from varying PG/VG liquids were generated using a digitally controlled vaping instrument and a commercially available ECIG, and analyzed for nicotine content by GC-MS. Particle mass and number distribution were determined using a six-stage cascade impactor and a fast particle spectrometer (TSI EEPS), with tightly controlled dilution and sampling biases. A Mie theory model was used to compute the aerosol scattering coefficients in the visible spectrum. Decreasing the PG/VG ratio resulted in a decrease in total particulate matter (TPM) and nicotine yield (R > 0.9, <.0001). Measured particle count median diameter ranged between 44-97nm, and was significantly smaller for PG liquids. Although the particle mass concentration was lower, aerosols produced using liquids that contained VG had an order of magnitude greater light scattering coefficients. These findings indicate that PG/VG ratio is a strong determinant of both nicotine delivery and user sensory experience.
Therkorn J, Thomas N, Scheinbeim J
… +1 more, Mainelis G
Aerosol Sci Technol
· 2017 · PMID 30774180
·
Full text
Passive bioaerosol samplers can improve environmental and health protection by enhancing the practicality and cost-effectiveness of air sampling. Here, we present the outdoor field testing of a novel, passive bioaerosol...Passive bioaerosol samplers can improve environmental and health protection by enhancing the practicality and cost-effectiveness of air sampling. Here, we present the outdoor field testing of a novel, passive bioaerosol sampler, the Rutgers Electrostatic Passive Sampler (REPS), based on the use of polarized, ferroelectric polymer film (poly(vinylidene fluoride)). Four 10-day-long field campaigns were conducted to compare total (culturable + non-culturable) and culturable bioaerosol collection efficiencies of REPS to passive samplers (PTFE settling filters and agar settling plates). These collection efficiencies were calculated relative to performance of an active, reference Button Sampler. Compared to passive PTFE filters, which exclusively rely on gravitational particle deposition, REPS collected a 7-fold higher total microorganism quantity. Relative to the Button Sampler, REPS collected 25% of the total number of bacteria and fungi and 65% of the culturable bacteria. Furthermore, REPS achieved this performance without any air movers, pumps, batteries or external power. Since the Button Samplers operated at 4 L/min, REPS was calibrated to have equivalent sampling rates of 2.6 L/min and 1.0 L/min for culturable bacteria and total microorganisms, respectively. These results suggest that REPS can passively collect airborne microorganisms, including culturable bacteria, with high efficiency over long-term sampling durations. REPS can provide better preservation of bacterial culturability because it has no active airflow, which desiccates microbes in active samplers. Since there are limited options available for long-term, unattended bioaerosol sampling, REPS can complement currently available bioaerosol sampling technologies for numerous environmental health applications, such as exposure assessment for epidemiology and monitoring aeroallergen trends.
Aerosol Sci Technol
· 2017 · PMID 30739977
·
Full text
Aerosol sampling and identification is vital for the assessment and control of particulate matter pollution, airborne pathogens, allergens, and toxins and their effect on air quality, human health, and climate change. In...Aerosol sampling and identification is vital for the assessment and control of particulate matter pollution, airborne pathogens, allergens, and toxins and their effect on air quality, human health, and climate change. In-situ analysis of chemical and biological airborne components of aerosols on a conventional filter is challenging due to dilute samples in a large collection region. We present the design and evaluation of a micro-well (µ-well) aerosol collector for the assessment of airborne particulate matter (PM) in the 0.5-3 micron size range. The design minimizes particle collection areas allowing for in-situ optical analysis and provides an increased limit of detection for liquid-based assays due to the high concentrations of analytes in the elution/analysis volume. The design of the collector is guided by computational fluid dynamics (CFD) modeling; it combines an aerodynamic concentrator inlet that focuses the aspirated aerosol into a narrow beam and a µ-well collector that limits the particle collection area to the µ-well volume. The optimization of the collector geometry and the operational conditions result in high concentrations of collected PM in the submillimeter region inside the µ-well. Collection efficiency experiments are performed in the aerosol chamber using fluorescent polystyrene microspheres to determine the performance of the collector as a function of particle size and sampling flow rate. The collector has the maximum collection efficiency of about 75% for 1 micron particles for the flow rate of 1 slpm. Particles bigger than 1 micron have lower collection efficiencies because of particle bounce and particle loss in the aerodynamic focusing inlet. Collected samples can be eluted from the device using standard pipettes, with an elution volume of 10-20 microliters. The transparent collection substrate and the distinct collection region, independent of particle size, allows for in-situ optical analysis of the collected PM.
Aerosol Sci Technol
· 2016 Nov · PMID 27928195
·
Full text
The ability to reproducibly produce and effectively collect electrosprayed polymeric microspheres with controlled morphology and size in bulk form is challenging. In this study, microparticles were produced by electrospr...The ability to reproducibly produce and effectively collect electrosprayed polymeric microspheres with controlled morphology and size in bulk form is challenging. In this study, microparticles were produced by electrospraying polycaprolactone (PCL) of various molecular weights and solution concentrations in chloroform, and by collecting materials on different substrates. The resultant PCL microparticles were characterized by optical and electron microscopy to investigate the effect of molecular weight, solution concentration, applied voltage, working distance, and flow rate on their morphology and size. The work demonstrates the key role of a moderate molecular weight and/or solution concentration in the formation of spherical PCL particles via an electrospraying process. Increasing the applied voltage was found to produce smaller and more uniform PCL microparticles. There was a relatively low increase in the particle average size with an increase in the working distance and flow rate. Four types of substrates were adopted to collect electrosprayed PCL particles: a glass slide, aluminium foil, liquid bath, and copper wire. Unlike 2D bulk structures collected on the other substrates, a 3D tubular structure of microspheres was formed on the copper wire which could find application in the construction of 3D tumor mimics.
Aerosol Sci Technol
· 2016 · PMID 27840546
·
Full text
A low-flow miniature differential mobility analyzer (mDMA) has been developed for compact field-portable mobility spectrometers to classify the submicrometer aerosol. The mDMA was designed for an ultra-low aerosol flow r...A low-flow miniature differential mobility analyzer (mDMA) has been developed for compact field-portable mobility spectrometers to classify the submicrometer aerosol. The mDMA was designed for an ultra-low aerosol flow rate of 0.05 L/min. At a sheath flow rate of 0.2 L/min, the mDMA's upper size limit was estimated to be about 921 nm. The mDMA has a classification zone of 2.54 cm long, an outer diameter of 2.54 cm, and an inner diameter of 1.778 cm. The design allows low-cost fabrication and easy assembly. Tandem DMA (TDMA) measurements were carried out to evaluate the performance of the mDMA. Its transfer function was described using Stolzenburg's model. The experimentally measured transfer function shows close agreement with the theory. The transmission efficiency was comparable to that of the Knutson-Whitby DMA for particles in the range of 10-1000 nm. The mobility resolution was comparable to that of the TSI 3085 nanoDMA at the same aerosol flow rate. The design features and performance of the mDMA make it suitable for compact field portable mobility size spectrometers for measurement of nanoparticles and submicrometer aerosol.
Park JH, Mudunkotuwa IA, Mines LW
… +3 more, Anthony TR, Grassian VH, Peters TM
Aerosol Sci Technol
· 2015 · PMID 26900208
·
Full text
A granular bed was designed to collect nanoparticles as an alternative to nylon mesh screens for use in a nanoparticle respiratory deposition (NRD) sampler. The granular bed consisted of five layers in series: a coarse m...A granular bed was designed to collect nanoparticles as an alternative to nylon mesh screens for use in a nanoparticle respiratory deposition (NRD) sampler. The granular bed consisted of five layers in series: a coarse mesh, a large-bead layer, a small-bead layer, a second large-bead layer, and a second coarse mesh. The bed was designed to primarily collect particles in the small-bead layer, with the coarse mesh and large-bead layers designed to hold the collection layer in position. The collection efficiency of the granular bed was measured for varying depths of the small-bead layer and for test particles with different shape (cuboid, salt particles; and fractal, and stainless steel and welding particles). Experimental measurements of collection efficiency were compared to estimates of efficiency from theory and to the nanoparticulate matter (NPM) criterion, which was established to reflect the total deposition in the human respiratory system for particles smaller than 300 nm. The shape of the collection efficiency curve for the granular bed was similar to the NPM criterion in these experiments. The collection efficiency increased with increasing depth of the small-bead layer: the particle size associated with 50% collection efficiency, , for salt particles was 25 nm for a depth of 2.2 mm, 35 nm for 3.2 mm, and 45 nm for 4.3 mm. The best-fit to the NPM criterion was found for the bed with a small-bead layer of 3.2 mm. Compared to cubic salt particles, the collection efficiency was higher for fractal-shaped particles larger than 50 nm, presumably due to increased interception.
Syedain ZH, Naqwi AA, Dolovich M
… +1 more, Somani A
Aerosol Sci Technol
· 2015 Sep · PMID 26884641
·
Full text
For infants born with respiratory distress syndrome (RDS), liquid bolus delivery of surfactant administered through an endotracheal tube is common practice. While this method is generally effective, complications such as...For infants born with respiratory distress syndrome (RDS), liquid bolus delivery of surfactant administered through an endotracheal tube is common practice. While this method is generally effective, complications such as transient hypoxia, hypercapnia, and altered cerebral blood flow may occur. Aerosolized surfactant therapy has been explored as an alternative. Unfortunately, past efforts have led to disappointing results as aerosols were generated outside the lungs with significant pharyngeal deposition and minimal intrapulmonary instillation. A novel aerosol generator (Microjet™) is evaluated herein for intrapulmonary aerosol generation within an endotracheal tube and tested with Curosurf and Infasurf surfactants. Compared with other aerosol delivery devices, this process utilizes low air flow (range 0.01-0.2 L/min) that is ideal for limiting potential barotrauma to the premature newborn lung. The mass mean diameter (MMD) of the particles for both tested surfactants was less than 4 μm, which is ideal for both uniform and distal lung delivery. As an indicator of phospholipid function, surfactant surface tension was measured before and after aerosol formation; with no significant difference. Moreover, this device has an outside diameter of <1mm, which permits insertion into an endotracheal tube (of even 2.0 mm). In the premature infant where intravenous access is either technically challenging or difficult, aerosol drug delivery may provide an alternative route in patient resuscitation, stabilization and care. Other potential applications of this type of device include the delivery of nutrients, antibiotics, and analgesics via the pulmonary route.
Afanou KA, Straumfors A, Skogstad A
… +6 more, Skaar I, Hjeljord L, Skare Ø, Green BJ, Tronsmo A, Eduard W
Aerosol Sci Technol
· 2015 · PMID 26855468
·
Full text
Fungal aerosols consist of spores and fragments with diverse array of morphologies; however, the size, shape, and origin of the constituents require further characterization. In this study, we characterize the profile of...Fungal aerosols consist of spores and fragments with diverse array of morphologies; however, the size, shape, and origin of the constituents require further characterization. In this study, we characterize the profile of aerosols generated from , and grown for 8 weeks on gypsum boards. Fungal particles were aerosolized at 12 and 20 L min using the Fungal Spore Source Strength Tester (FSSST) and the Stami particle generator (SPG). Collected particles were analyzed with field emission scanning electron microscopy (FESEM). We observed spore particle fraction consisting of single spores and spore aggregates in four size categories, and a fragment fraction that contained submicronic fragments and three size categories of larger fragments. Single spores dominated the aerosols from (median: 53%), while the submicronic fragment fraction was the highest in the aerosols collected from (median: 34%) and (median: 31%). Morphological characteristics showed near spherical particles that were only single spores, oblong particles that comprise some spore aggregates and fragments (<3.5 m), and fiber-like particles that regroup chained spore aggregates and fragments (>3.5 m). Further, the near spherical particles dominated the aerosols from (median: 53%), while oblong particles were dominant in the aerosols from (68%) and (55%). Fiber-like particles represented 21% and 24% of the aerosols from and , respectively. This study shows that fungal particles of various size, shape, and origin are aerosolized, and supports the need to include a broader range of particle types in fungal exposure assessment.
Soo JC, Monaghan K, Lee T
… +2 more, Kashon M, Harper M
Aerosol Sci Technol
· 2016 Jan · PMID 26834310
·
Full text
The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 m pore sizes), polycarbonate (0.4, 0.8,...The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 m pore sizes), polycarbonate (0.4, 0.8, 2, and 5 m pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 m pore sizes), polyvinyl chloride (PVC; 0.8 and 5 m pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 m pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10-400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes.
Blair SL, Epstein SA, Nizkorodov SA
… +1 more, Staimer N
Aerosol Sci Technol
· 2015 · PMID 26726281
·
Full text
Tobacco-free electronic cigarettes (e-cigarettes), which are currently not regulated by the FDA, have become widespread as a "safe" form of smoking. One approach to evaluate the potential toxicity of e-cigarettes and oth...Tobacco-free electronic cigarettes (e-cigarettes), which are currently not regulated by the FDA, have become widespread as a "safe" form of smoking. One approach to evaluate the potential toxicity of e-cigarettes and other types of potentially "reduced-harm" cigarettes is to compare their emissions of volatile organic compounds (VOCs), including reactive organic electrophillic compounds such as acrolein, and particulate matter to those of conventional and reference cigarettes. Our newly designed fast-flow tube system enabled us to analyze VOC composition and particle number concentration in real-time by promptly diluting puffs of mainstream smoke obtained from different brands of combustion cigarettes and e-cigarettes. A proton transfer reaction time-of-flight mass spectrometer (PTRMS) was used to analyze real-time cigarette VOC emissions with a 1 s time resolution. Particles were detected with a condensation particle counter (CPC). This technique offers real-time analysis of VOCs and particles in each puff without sample aging and does not require any sample pretreatment or extra handling. Several important determining factors in VOC and particle concentration were investigated: (1) puff frequency; (2) puff number; (3) tar content; (4) filter type. Results indicate that electronic cigarettes are not free from acrolein and acetaldehyde emissions and produce comparable particle number concentrations to those of combustion cigarettes, more specifically to the 1R5F reference cigarette. Unlike conventional cigarettes, which emit different amounts of particles and VOCs each puff, there was no significant puff dependence in the e-cigarette emissions. Charcoal filter cigarettes did not fully prevent the emission of acrolein and other VOCs.
Aerosol Sci Technol
· 2016 · PMID 28871213
·
Full text
We compared the performance of a low-cost (∼$500), compact optical particle counter (OPC, OPC-N2, Alphasense) to another OPC (PAS-1.108, Grimm Technologies) and reference instruments. We measured the detection efficiency...We compared the performance of a low-cost (∼$500), compact optical particle counter (OPC, OPC-N2, Alphasense) to another OPC (PAS-1.108, Grimm Technologies) and reference instruments. We measured the detection efficiency of the OPCs by size from 0.5 to 5 μm for monodispersed, polystyrene latex (PSL) spheres. We then compared number and mass concentrations measured with the OPCs to those measured with reference instruments for three aerosols: salt, welding fume and Arizona road dust. The OPC-N2 detection efficiency for monodispersed was similar to the PAS-1.108 for particles larger than 0.8 μm (minimum of 79% at 1 μm and maximum of 101% at 3 μm). For 0.5-μm particles, the detection efficiency of OPCN2 was underestimated at 78%, whereas PAS-1.108 overestimated concentrations by 183%. The mass concentrations from the OPCs were linear (r ≥ 0.97) with those from the reference instruments for all aerosols, although the slope and intercept were different. The mass concentrations were overestimated for dust (OPC-N2, slope = 1.6; PAS-1.108, slope = 2.7) and underestimated for welding fume (OPC-N2, slope = 0.05; PAS-1.108, slope = 0.4). The coefficient of variation (CV, precision) for OPC-N2 for all experiments was between 4.2% and 16%. These findings suggest that, given site-specific calibrations, the OPC-N2 can provide number and mass concentrations similar to the PAS-1.108 for particles larger than 1 μm.
Mines LWD, Park JH, Mudunkotuwa IA
… +3 more, Anthony TR, Grassian VH, Peters TM
Aerosol Sci Technol
· 2016 · PMID 28867869
·
Full text
Porous polyurethane foam was evaluated to replace the eight nylon meshes used as a substrate to collect nanoparticles in the Nanoparticle Respiratory Deposition (NRD) sampler. Cylindrical (25-mm diameter by 40-mm deep) f...Porous polyurethane foam was evaluated to replace the eight nylon meshes used as a substrate to collect nanoparticles in the Nanoparticle Respiratory Deposition (NRD) sampler. Cylindrical (25-mm diameter by 40-mm deep) foam with 110 pores per inch was housed in a 25-mm-diameter conductive polypropylene cassette cowl compatible with the NRD sampler. Pristine foam and nylon meshes were evaluated for metals content via elemental analysis. The size-selective collection efficiency of the foam was evaluated using salt (NaCl) and metal fume aerosols in independent tests. Collection efficiencies were compared to the nanoparticulate matter (NPM) criterion and a semi-empirical model for foam. Changes in collection efficiency and pressure drop of the foam and nylon meshes were measured after loading with metal fume particles as measures of substrate performance. Substantially less titanium was found in the foam (0.173 μg sampler) compared to the nylon mesh (125 μg sampler), improving the detection capabilities of the NRD sampler for titanium dioxide particles. The foam collection efficiency was similar to that of the nylon meshes and the NPM criterion (R = 0.98, for NaCl), although the semi-empirical model underestimated the experimental efficiency (R = 0.38). The pressure drop across the foam was 8% that of the nylon meshes when pristine and changed minimally with metal fume loading (~ 19 mg). In contrast, the pores of the nylon meshes clogged after loading with ~ 1 mg metal fume. These results indicate that foam is a suitable substrate to collect metal (except for cadmium) nanoparticles in the NRD sampler.
Sousan S, Koehler K, Thomas G
… +4 more, Park JH, Hillman M, Halterman A, Peters TM
Aerosol Sci Technol
· 2016 · PMID 28867868
·
Full text
Low-cost sensors are effective for measuring the mass concentration of ambient aerosols and secondhand smoke in homes, but their use at concentrations relevant to occupational settings has not been demonstrated. We measu...Low-cost sensors are effective for measuring the mass concentration of ambient aerosols and secondhand smoke in homes, but their use at concentrations relevant to occupational settings has not been demonstrated. We measured the concentrations of four aerosols (salt, Arizona road dust, welding fume, and diesel exhaust) with three types of low-cost sensors (a DC1700 from Dylos and two commodity sensors from Sharp), an aerosol photometer, and reference instruments at concentrations up to 6500 μg/m. Raw output was used to assess sensor precision and develop equations to compute mass concentrations. EPA and NIOSH protocols were used to assess the mass concentrations estimated with low-cost sensors compared to reference instruments. The detection efficiency of the DC1700 ranged from 0.04% at 0.1 μm to 108% at 5 μm, as expected, although misclassification of fine and coarse particles was observed. The raw output of the DC1700 had higher precision (lower coefficient of variation, CV = 7.4%) than that of the two sharp devices (CV = 25% and 17%), a finding attributed to differences in manufacturer calibration. Aerosol type strongly influenced sensor response, indicating the need for on-site calibration to convert sensor output to mass concentration. Once calibrated, however, the mass concentration estimated with low-cost sensors was highly correlated with that of reference instruments (R=0.99). These results suggest that the DC1700 and Sharp sensors are useful in estimating aerosol mass concentration for aerosols at concentrations relevant to the workplace.
Aerosol Sci Technol
· 2016 · PMID 28663667
·
Full text
A cavity ring-down spectrometer and condensation particle counter were used to investigate the limitations in the separation of singly and multiply charged aerosol particles by a tandem differential mobility analyzer (DM...A cavity ring-down spectrometer and condensation particle counter were used to investigate the limitations in the separation of singly and multiply charged aerosol particles by a tandem differential mobility analyzer (DMA) and aerosol particle mass analyzer (APM). The impact of particle polydispersity and morphology was investigated using three materials: nearly-monodisperse polystyrene latex nanospheres (PSL); polydisperse, nearly-spherical ammonium sulfate (AS) and polydisperse lacey fractal soot agglomerates. PSL and AS particles were easily resolved as a function of charge. For fresh soot, the presence of multiply charged particles severely affects the isolation of the singly charged particles. In cases where the DMA-APM was unable to fully resolve the singly charged particles of interest, the peak mass deviated by up to 13 % leading to errors in the mass specific extinction cross section of over 100 %. For measurements of non-spherical particles, non-symmetrical distributions of concentration as a function of mass were a sign of the presence of multiply charged particles. Under these conditions, the effects of multiply charged particles can be reduced by using a second charge neutralizer after the DMA and prior to the APM. Dilution of the aerosol stream serves to decrease the total number concentration of particles and does not remove the contributions of multiply charged particles.
Aerosol Sci Technol
· 2016 · PMID 28603336
·
Full text
The aim of this study was to apply a direct-reading aerosol instrument method and an elemental carbon (EC) analysis method to measure the mass-based penetration of single-walled carbon nanotubes (SWCNTs) and multi-walled...The aim of this study was to apply a direct-reading aerosol instrument method and an elemental carbon (EC) analysis method to measure the mass-based penetration of single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs) through elastomeric half-mask respirators (EHRs) and filtering facepiece respirators (FFRs). For the direct-reading aerosol instrument method, two scanning mobility particle sizer/aerodynamic particle sizer systems were used to simultaneously determine the upstream (outside respirator) and downstream (inside respirator) test aerosols. For the EC analysis method, upstream and downstream CNTs were collected on filter cassettes and then analyzed using a thermal-optical technique. CNT mass penetrations were found in both methods to be within the associated efficiency requirements for each type and class of the respirator models that were tested. Generally, the penetrations of SWCNTs and MWCNTs had a similar trend with penetration being the highest for the N95 EHRs, followed by N95 FFRs, P100 EHRs, and P100 FFRs. This trend held true for both methods; however, the CNT penetration determined by the direct-reading aerosol instrument method (0.009-1.09% for SWCNTs and 0.005-0.21% for MWCNTs) was greater relative to the penetration values found through EC analysis method (0.007-0.69% for SWCNTs and 0.004-0.13% for MWCNTs). The results of this study illustrate considerations for how the methods can be used to evaluate penetration of morphologically complex materials through FFRs and EHRs.
We describe development of a Portable Aerosol Mobility Spectrometer (PAMS) for size distribution measurement of submicrometer aerosol. The spectrometer is designed for use in personal or mobile aerosol characterization s...We describe development of a Portable Aerosol Mobility Spectrometer (PAMS) for size distribution measurement of submicrometer aerosol. The spectrometer is designed for use in personal or mobile aerosol characterization studies and measures approximately 22.5 × 22.5 × 15 cm and weighs about 4.5 kg including the battery. PAMS uses electrical mobility technique to measure number-weighted particle size distribution of aerosol in the 10-855 nm range. Aerosol particles are electrically charged using a dual-corona bipolar corona charger, followed by classification in a cylindrical miniature differential mobility analyzer. A condensation particle counter is used to detect and count particles. The mobility classifier was operated at an aerosol flow rate of 0.05 L/min, and at two different user-selectable sheath flows of 0.2 L/min (for wider size range 15-855 nm) and 0.4 L/min (for higher size resolution over the size range of 10.6-436 nm). The instrument was operated in voltage stepping mode to retrieve the size distribution, which took approximately 1-2 minutes, depending on the configuration. Sizing accuracy and resolution were probed and found to be within the 25% limit of NIOSH criterion for direct-reading instruments (NIOSH 2012). Comparison of size distribution measurements from PAMS and other commercial mobility spectrometers showed good agreement. The instrument offers unique measurement capability for on-person or mobile size distribution measurements of ultrafine and nanoparticle aerosol.
Turner J, Hernandez M, Snawder JE
… +2 more, Handorean A, McCabe KM
Aerosol Sci Technol
· 2015 · PMID 26412929
·
Full text
Epidemiological studies have shown that exposure to airborne particulate matter can be an important risk factor for some common respiratory diseases. While many studies have shown that particulate matter exposures are as...Epidemiological studies have shown that exposure to airborne particulate matter can be an important risk factor for some common respiratory diseases. While many studies have shown that particulate matter exposures are associated with inflammatory reactions, the role of specific cellular responses in the manifestation of primary hypersensitivities, and the progression of respiratory diseases remains unclear. In order to better understand mechanisms by which particulate matter can exert adverse health effects, more robust approaches to support studies are warranted. In response to this need, a group of accepted toxicology assays were adapted to create an analytical suite for screening and evaluating the effects of important, ubiquitous atmospheric pollutants on two model human lung cell lines (epithelial and immature macrophage). To demonstrate the utility of this suite, responses to intact diesel exhaust particles, and mass-based equivalent doses of their organic extracts were examined. Results suggest that extracts have the potential to induce greater biological responses than those associated with their colloidal counterpart. Additionally, macrophage cells appear to be more susceptible to the cytotoxic effects of both intact diesel exhaust particles and their organic extract, than epithelial cells tested in parallel. As designed, the suite provided a more robust basis for characterizing toxicity mechanisms than the analysis of any individual assay. Findings suggest that cellular responses to particulate matter are cell line dependent, and show that the collection and preparation of PM and/or their extracts have the potential to impact cellular responses relevant to screening fundamental elements of respiratory toxicity.